NYC Law Department release
Independent mirror · updated as the City releases more · v1.2.6
← Document results/DEP Box 37/1 BROADWAY; Block: 13; Lot: 1; BIN: 1000043; 1-3 Greenwich Street, 1 Battery Place
Document / 5 pages

Insignia/ESG survey report for 1 Broadway, March 2002

Machine-extracted title · confidence 90%

Letter from Insignia/ESG reporting on a survey performed at 1 Broadway on March 5, 2002.

NYC-WTC_000105460–000105464

Folder label: “1 BROADWAY; Block: 13; Lot: 1; BIN: 1000043; 1-3 Greenwich Street, 1 Battery Place

Page image
Scanned page image, NYC-WTC_000105461
OCR text

OCR status: ok · source: pdftotext

NYC 9111 Public Portal Document

ambient group irx. NATIOYAL HEADQUARTERS

Indoor envirorenental quality surveys 55 WFST 39m VTRRET 12m MOOR Water treatment consulting NEW YORK, NEW YORK 10018 Asbestos & lead field services TEt; (212) 944-4615 Regulatory compliance programs FAX: (212) 944-46r8 Air, water & soil analytical laboratories WEB: WWW.AMBXENTGROUP.coM

March 11, 2002

Mr. Steven A. Donahue Insignia/ESG, Inc. One Broadway New York, NY 10004

Re: Exterior Assessment of Possible Building Contamination Project #220252

Dear Mr.Donahue: On March 5, 2002 at the request of the Building's Management (Insignia/ESG), Ambient Group, Inc. collected bulk samples of suspect dust/debris material located on several of the building's rooflsetbacks. The purpose of the sampling was to determine whether the possibility of asbestos contamination occurred to the exterior of the building as a result of the collapse of the World Trade Center. Also a recent visual survey by the New York City Department of Environmental Protection (NYCDEP) indicated that suspect dust was observed on the building's exterior. Therefore, Ambient was requested to collect appropriate representative samples of the NYCDEP observed suspect materials. A total of four (4) bulk samples were collected of suspect dust/debris material from selected roof/setback levels. All of the samples analyzed indicated the presence of asbestos, in an amount between 0.3% and 2%. All samples were analyzed by Polarized Light Microscopy (NYSDOH ELAP Method 198.1). Based on the above it is recommended that the Building undergo a cleanup of exterior roof/setback surfaces in accordance with the NYCDEP's roof decontamination procedures (copy attached). Also attached please find a description of the bulk sampling and sample analysis protocols used during this project and the Bulk Sample Laboratory Data Reports for this project. Should you have any questions, please do not hesitate to call. Sincerely, 'gned-£or Ambient Group, Inc. by:

J sep Cianci, Project Manager

GLEN COVE, NY MIAMI, FL CHICAGO, It ORANGE, CA

516 609-000g 305 860-0101 312 527- 5526 714 282-1525

£ool animuoa •V uaeaag L6699tUTZ %V3 £S:vT ZOOZ/ZZ/£0

NYC-WTC 000105461

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000105461Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

No available related records indexed in this group.

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Page similarity is temporarily unavailable or this page has no indexed vector.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →