METRO LOFT MGMT PAGE 02 02/1.9/2002 . 10150 , .„2127062525 P . u.?

Envxronmentai Management Solutions of NY, Inc.______________ Woodsid. Avrnue, Biiatcliff Minor. NY 10510 • Tel 914 762 6333 • Fix 914 762 5STS

October 10.2001 METRO 17 John Street New York, New York 10038 Attn'Jack B-tmian Re; Air Sample Results: 17 John Street New York. NY Dear Mr. BeTtnan; Following the collapse of the World Trade Centers and associated properties, EMS was reUined by your ofTice to perform baseline sampling within the building to detennlne if airborne asbestos was present. EMS of NY tested representative floors as detailed in the anlaytical results enclosed tiad subjected tho samples to analysis via Transmission Electron Microscopy (TEM). TEM anslj^is is deemed state of the art and is able to distinguish between asbestos and non*asbcsto8 fibers. It is important to note that during the testing, the building was operating under normal occupaiicy exposure. The results that were obtained indicated that at the time of testing no asbestos fibers were detected tn the air samples collected. However, non-asbeatos structures - gypsom and cellulose components of sheetrock, were present. Current acceptable levels as act forth by the Environmental Protection Agency etc set ut 70 s/mm*. The standard of 70 a/mn? is used to determine whether background levels or airtome levels following an abatement project are acceptable for human occupancy. If the concentration exceed 70 s/mm’, then additional testing along with clean>up and possible protective equipment should be initiated for precautionary purposes. Overall, based upon the sampling results, the air quality in regards to asbestos, according to ERA standards, is acceptable. If you have any questions or require additional information, please contact me.

Marc Rutstein Vice President.

hazard ide ntifi ca lio n rijk tninagcmenc impact atjc*»menc

CITY_21MC100_002950107

NYC-WTC_000282337

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000282337Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000230980

Application submitted to the DEP regarding cleaning procedures for a residential condominium, including exterior facade and interior duct work.

Similar indexed content

Compare copies and versions →