PARTICLE FILTER ROOMS COUNT TYPE LOCATION RESULTS
216 525,000 2” Odor Guard - 2” 4 ply Pleat Classroom 70% Reduction of Particulate 112 440,000 2” Odor Guard - 2” 4 ply Pleat Kindergarten 75% Reduction of Particulate -I- 95% Bag
Stuyvesant High School
Outside Air -1,400,000 Reduction of 60% (Cleanup of WTC Site)
PARTICLE FILTER ROOMS COUNT TYPE LOCATION RESULTS
Vestibule 1,225,000 2” Odor Guard-2” 4 ply Pleat 35% Reduction of Particulate Guard 831,000 2” Odor Guard-2” 4 ply Pleat Classroom 53% Reduction of Particulate Desk Auditorium 1,130,000 2” Odor Guard-2” 4 ply Pleat 35% Reduction of Particulate (units not running) Faculty 545,i Unit Ventilator-2” Odor Guard 69% Reduction of Particulate Dining 5th Floor 630,000 2” Odor Guard-95% Bag 64% Reduction of Particulate Corridor Filter 511 680,000 Unit Ventilator-2” Odor Guard 61 % Reduction of Particulate o'” Fl Gym 700,000 2” Odor Guard-2” 4 ply Pleat 60% Reduction of Particulate 10th Fl. 570,000 2” Odor Guard-95% Bag 67% Reduction of Particulate Corridor Filter 1017 700,000 Unit Ventilator-2” Odor Guard 60% Reduction of Particulate 1010 360,000 Unit Ventilator-2” Odor Guard 79% Reduction of Particulate 1006 500,000 Unit Ventilator-2” Odor Guard 71% Reduction of Particulate 1004 410,000 Unit Ventilator-2” Odor Guard 77% Reduction of Particulate 9’” Fl. 380,000 Unit Ventilator-2” Odor Guard 78% Reduction of Particulate Corridor Music 690,000 2” Odor Guard-2” 4 ply Pleat 61% Reduction of Particulate Room 133 Music 600,000 2” Odor Guard-2” 4 ply Pleat 66% Reduction of Particulate Room 125
Table 6-2 provides a graphical comparison of the effectiveness of the filter replacement program. This graph was prepared by ATC based on particulate levels sampled from December to the end of March. The graph, based on the indoor readings at Stuyvesant High School, illustrates that after the filter replacement program on January 23, 2002
A:\6_RetronttingHVAC_R.CascoM.doc
Page 22
CITY_21MC100_010274200
NYC-WTC_000278813
OCR can misread numbers and units. Confirm readings against the page image before using them.
Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.
NYC-WTC_000322244
Consulting report cover page for HVAC retrofitting and air quality at Ground Zero.
34 shared non-person entities · 1 shared topics · similarity 0.994
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000453548
Board of Education disaster response summary for schools near WTC site.
32 shared non-person entities · 1 shared topics · similarity 0.996
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000276036
Document discussing lessons learned in children's environmental health related to Ground Zero sites.
36 shared non-person entities · 1 shared topics · similarity 0.961
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000236896
Draft protocol document outlining daily ambient air and dust sampling procedures for PS/IS 89 following the World Trade Center tragedy.
16 shared non-person entities · similarity 0.954
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000319809
Document describing MS/PS 85M occupancy and recovery operations related to WTC.
23 shared non-person entities · similarity 0.954
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000145027
Notice from NYC Law Department instructing staff to preserve World Trade Center documents for potential legal actions.
19 shared non-person entities · 1 shared topics · similarity 0.953
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000455806
Safety and health survey of a DOE office space and HVAC system following employee complaints at 52 Chambers Street.
9 shared non-person entities · similarity 0.952
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000317925
Draft chain-of-custody outlining ambient and residential dust sampling near WTC with exposure rationale.
13 shared non-person entities · similarity 0.951
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000250253
ATC cost estimate letter for environmental services at six schools affected by 9/11.
16 shared non-person entities · similarity 0.950
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000250241
Laboratory report page with OCR-garbled content; appears to be environmental test results related to PS 89M.
17 shared non-person entities · similarity 0.950
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000125845
Draft fact sheet from DOH and DEP addressing tenant concerns regarding asbestos fibers at 105 Duane Street.
22 shared non-person entities · 1 shared topics · similarity 0.950
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000385871
Ambient air and dust sampling protocol for High School for Leadership & [name] (M 894).
16 shared non-person entities · similarity 0.949
machine-extracted · confidence unavailable · Check page ↗Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.
NYC-WTC_000322244
Consulting report cover page for HVAC retrofitting and air quality at Ground Zero.
Similarity score 0.998 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000322244
Consulting report cover page for HVAC retrofitting and air quality at Ground Zero.
Similarity score 0.957 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000322244
Consulting report cover page for HVAC retrofitting and air quality at Ground Zero.
Similarity score 0.949 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000276036
Document discussing lessons learned in children's environmental health related to Ground Zero sites.
Similarity score 0.945 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000322244
Consulting report cover page for HVAC retrofitting and air quality at Ground Zero.
Similarity score 0.944 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000453548
Board of Education disaster response summary for schools near WTC site.
Similarity score 0.940 (not a probability)
machine-extracted · confidence unavailable · Check page ↗Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.
NYC-WTC_000453548
Board of Education disaster response summary for schools near WTC site.
Similar indexed content
NYC-WTC_000322244
Consulting report cover page for HVAC retrofitting and air quality at Ground Zero.
Similar indexed content
NYC-WTC_000276036
Document discussing lessons learned in children's environmental health related to Ground Zero sites.
Similar indexed content
NYC-WTC_000236896
Draft protocol document outlining daily ambient air and dust sampling procedures for PS/IS 89 following the World Trade Center tragedy.
Similar indexed content
NYC-WTC_000319809
Document describing MS/PS 85M occupancy and recovery operations related to WTC.
Similar indexed content