NYC 9/11 Public Portal Document

Burns and Roe has evaluated and cfm tested several types of filter media and has recommended the 2” Odor Guard as the preferred filter, base on its particulate efficiency rated at 85-90% at 1 micron and its carbon- activated filter to eliminate odors. This filter will be installed and has been shipped.

Due to concerns that this may not be the best filter, the Board of Education has authorized ATC associates, environmental consultants to the Bd, of Ed, to perform environmental testing to assist Burns and Roe in the filter evaluation program.

Discussion with Andreas Andreou of ATC has resulted in the following proposed program: ATC will monitor 4 classrooms inl^Bk and Six classrooms in Stuyvesant High School for particulate on a continuous basis for a 2-4 week period. Values will be taken on a 15-minute interval, data logged and plotted for comparison.

Stuyvesant High School - Sampling Program - Particulate

Six classrooms on the 5th’* floor, three on the South Side and three on the North side, will be sampled. Filters to be installed consist of the following:

Classroomi: 4 ply pleated filter media to serve as baseline.

Classroom 2: 2” Odor Guard III as provided by Air Engineering: 2”- 9" x 36".''

' A'WL is requested Io retrofit UV’s in this classroom with a 2” filter racks

CITY_21MC100_012173011

NYC-WTC_000276166

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000276166Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000106411 · Box DEP Box 37

Union memorandum regarding environmental monitoring and cleanup protocols following the closure of Stuyvesant High School after the September 11 attacks.

Similar indexed content

NYC-WTC_000149798 · Box DEP Box 10

Generic form or header page from the Department of Environmental Protection regarding general World Trade Center notices and requests.

Similar indexed content

Compare copies and versions →