Office. The analytical data obtained from the bulk composite was utilized in
identifying COPC concentrations present in settled dust, determining the applicability
of regulatory standards, and identifying potential health and safety concerns. The
Chiropractor Office was selected, based upon visual observation, as being
representative of a “worst case scenario” for the various units in the Pilot Study
building.
Asbestos
Before cleaning samples - Pre-cleaning air, micro vacuum, and wipe samples were
collected for asbestos. The air samples were analyzed for PCM and PCMe. The
PCM results indicate that one sample was above the secondary numeric criterion of
0.01 f/cc and one was below this value. The TEM PCMe results were both below the
detection limit and below the primary numeric criterion of 0.0009 s/cc. All four of the
micro vacuum samples detected chrysotile above the detection limit. All five wipe
samples were also above the detection limit with chrysotile being detected in all five
samples and amosite in two of the five samples.
Post Cleaning Samples, Test 4A - Post-cleaning air, micro vacuum, and wipe
samples were collected for asbestos. The air samples were analyzed for PCM and
PCMe; however, none of the analyses could be analyzed due to overloading of
particulate material.
The results of the four micro vacuum samples indicate that asbestos was present at
levels lower than those observed before cleaning.
The results of the wipe samples indicate that asbestos was present in all five samples
at lower concentrations than those observed before cleaning. One of the five samples
was identified as being below the detection limit.
Post P' Cleaning Samples. Test 4B - Post-cleaning air and wipe samples were
collected for asbestos. The air samples were analyzed for PCM, TEM AHERA, and
PCMe. The PCM results indicate that one sample could not be analyzed due to
particulate overloading and two were above the secondary numeric criterion of 0.01
f/cc. The TEM AHERA results indicate that two samples could not be analyzed due
to particulate overloading and one sample was above the secondary numeric criterion
of 0.022 S/cc. The TEM PCMe results indicate that two of the samples could not be
analyzed due to particulate overloading and one results was above the primary
numeric criterion of 0.0009 S/cc.
The results of the five wipe samples indicate that asbestos was present in all five
samples at lower concentrations than those observed before cleaning.