for asbestos. These samples indicate that asbestos was present in the unit prior to cleaning. All three micro vacuum samples detected chrysotile above the detection limit. Three of the four wipe samples were below the detection limit; however, chrysotile was detected in two of these samples. The fourth wipe sample was above the detection limit

Post Cleaning - Three air samples, three micro vacuum samples, and five wipe samples were collected. The three air samples were analyzed using PCM, TEM AHERA, and PCMe. The PCM, TEM AHERA and PCMe analyses could not be conducted due to overloading of particulate material. Due to inconclusive asbestos air results, a second cleaning was conducted.

The results for the three micro vacuum samples indicate that asbestos was present at levels similar to or higher than those observed before cleaning. One of the samples was identified as non-detect, although asbestos was present below the detection limit.

The results for the five wipe samples that were collected indicate that asbestos was present in all five samples, although two samples were below the detection limit. The concentrations observed were similar to or higher than the pre-cleaning samples

Post 2'“^ Cleaning - Three asbestos air samples were collected after the second cleaning. The samples were analyzed for PCM, TEM AHERA, and PCMe. The PCM results could not be obtained due to the filter being overloaded with particulate material. The TEM AHERA results for each sample were below the detection limit and below the secondary numeric criterion of 0.022 S/cc. The PCMe results were all below the primary clearance criterion of 0.0009 S/cc, with all three of the samples below the detection limit. This indicates that the cleaning techniques used were able to reduce the particulate matter in the unit after the second cleaning, which permitted samples to be analyzed. The results of the analysis indicated that asbestos concentrations were below the primary clearance criterion of 0.0009 S/cc.

Dioxin Before Cleaning Samples - Three pre-cleaning wipe samples were collected and analyzed for dioxin. The results indicate that dioxin was present; however, the TEQ concentration for each sample was below the primary clearance criterion of 4 ng/m^.

Post P‘ Cleaning Samples - Four post-cleaning wipe samples were collected and analyzed for dioxin. The results indicate that the TEQ concentration for each sample was below the primary clearance criterion of 4 ng/m^.

Gypsum Before Cleaning Samples - Pre-cleaning air samples were not collected

Post P‘ Cleaning Samples - Two air samples were collected after the first cleaning. Gypsum was not detected in any sample.

Posi 2^ Cleaning Samples - Two air samples were collected after the second cleaning.

59

CITY_21MC100_011063429

NYC-WTC_000363121

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000363121Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →