Asbestos
Before Cleaning Samples - Pre-cleaning micro vacuum and wipe samples were collected for
asbestos. These samples indicate that asbestos was present in the unit prior to cleaning.
Three of the four micro vacuum samples detected chrysotile and all five wipe samples
detected chrysotile, although two of the samples were below the detection limit.
Post P‘ Cleaning - There were post-cleaning air, micro vacuum, and wipe samples collected.
The three air samples were analyzed using PCM, TEM AHERA, and TEM PCMe. The PCM
results were all below the secondary numeric criterion of 0.01 f/cc. The TEM AHERA and
TEM PCMe analysis could not be conducted due to overloading of particulate material.
The results for the three micro vacuum samples indicate that asbestos was present at levels
generally lower than those observed before cleaning. One of the samples was identified as
non-detect, although asbestos was detected below the detection limit.
The results for the five wipe samples that were collected indicate that asbestos was present in
two of the five samples at lower concentrations than the pre-cleaning samples. One of the
two samples in which asbestos was detected was below the detection limit.
Post 2"'^ Cleaning - There were six asbestos air samples collected after the second cleaning.
The samples were analyzed for PCM, TEM AHERA, and TEM PCMe. The PCM results
were all below the secondary numeric criterion of 0.01 f/cc and were at lower concentrations
than after the first cleaning. The TEM AHERA results were all below the secondary numeric
criterion of 0.022 S/cc with two of the six samples being below the detection limit. The TEM
PCMe results were all below the primary numeric criteria of 0.0009 S/cc with three of the six
samples being below the detection limit.
Dioxin
Before Cleaning Samples - There were four pre-cleaning wipe samples collected and
analyzed for dioxin. The results indicate that there was dioxin present; however, the TEQ
concentrations for each sample were below the primary numeric criterion of 4 ng/m^.
Post P' Cleaning Samples - There were four post-cleaning wipe samples collected-and
analyzed for dioxin. The results indicate that the concentrations of dioxin detected were
lower than the pre-cleaning samples and the TEQ concentrations for each sample were below
the primary numeric criterion of 4 ng/mf
Gypsum
Before Cleaning Samples - There were four pre-cleaning wipe samples collected. The results
indicate that gypsum was not detected.