Mercury Vapor Analyzer. Measurements were performed at the breathing zone of infants and adults
(6 inches and 5 feet above the floor), using continuous, real-time monitoring and data logging of
mercury levels. Further explanation of mercury sampling activities and results are included in
Attachment 16.
SECTION 4 - DISCUSSION OF RESULTS
Other Activities:
Mercury Sampling demonstrated that mercury contamination was not a concern in the building.
Results of the mercury vapor investigation using the Lumex analyzer revealed a mean of 53.6 ng/m3
(range 3-210 ng/m3), thus demonstrating that air samples within the building tested below the
USEPA's Reference Concentration of 300 ng/m3. The instrument has a Detection Limit of 2 ng/m3 .
Analytical Results and Discussion
Introduction
The analytical results and a brief discussion for each unit is provided in this section. The format for
each unit presents the physical infonnation about each unit, the cleaning methods that were used, the
number of times the unit was cleaned, and a narrative description of the analytical results. The
analytical results are presented in alphabetical-order and provide details for samples that were
4^^ collected before any cleaning event and after each specific cleaning event. If a compound is not
present for the unit or if a sample type is not present for that compound, then it is not listed in the
text. The narratives follow the tables in Attachment 14 which provide the actual analytical results
for each sample that was collected and analyzed. There is a key at the beginning of Attachment 14
that explains the units associated with each result. For example, results that are reported in units of
f/cc are associated with PCM analyses and S>5u/cc are associated with TEM PCMe analyses.
Unit 2A - This unit is located on the second floor. It is a 1,335 sq. ft. loft with one bedroom facing
Cedar Street. There was minimal dust accumulation in the dwelling with the exception of the
baseboard-heating units. The windows were not blown-in and the unit has hardwood floors. All
personal items were disposed except for a couch and chairs.
Cleaning method - This unit was cleaned using test method IB. Test method IB used a
Ridgid shop vacuum and Hoover upright vacuum for vacuuming the floors and other
surfaces. Neither vacuum had a HEPA filter; however, an air filtration device (AFD) was
used during the cleaning process. In addition, all horizontal surfaces were wet wiped. This
cleaning method was used for each cleaning event.
Numeric Criteria - This unit met the numeric criteria listed in Table 1 for each compound
after being cleaned twice.