NYC 9/11 Public Portal Document
INTERNAL REVIEW DRAFT
3.G.I. Validation
The validation of all organic and inorganic analytical data was performed in accordance with the
QAPP. Validation of inorganic data was performed by the Region 2 RST. Validation of organic
data was performed by EPA Region 2 personnel.
3,G.2. Reporting
All analytical results were tabulated subsequent to validation and are provided in Attachment 14.
3.G.3. Difficulties Encountered and Resolutions
A summary of all difficulties that were encountered in the sampling program along with an
explanation of how they were resolved is presented in Attachment 15, Sampling and Analytical
Difficulties Encountered and Resolutions.
3.H. Supplemental Sampling Activities
3.H.I. Sampling of "Non-Study" Units
Three commercial units located within the Study building, but not part of the initial Study, were also
cleaned by EPA. These units were cleaned as a condition of access from the owner of the building.
Pre-cleanup samples collected from the two of the three non-Study commercial units (ie. Food
Exchange, Lemongrass Grill) were limited to the collection of wipe samples from within the HVAC
ducts. Analysis of these samples included lead,, MMVF, silica, asbestos. Other pre-cleanup
samples were collected from the remaining non-Study commercial unit (ie. Barber Shop) included as
a bulk sample of insulation material which was collected to confirm its asbestos content. Pre-cleanup
wipe samples were also collected for lead, dioxin and PAHs analysis.
Post-cleanup area air samples were collected from the three non-Study commercial units (Barber
Shop, Lemongrass Grill, and Food Exchange). The analyses for these samples included MMVF,
asbestos (PCM, TEM), silica, and lead. Additional air samples were collected in the Lemongrass
Grill and Food Exchange in close proximity to the HVAC return ducts in order to evaluate the
effectiveness of the HVAC cleaning method.
Post-cleanup wipe samples were collected from the inside surfaces of the HVAC ducts within two of
the three non-Pilot Units (Lemongrass Grill, Food Exchange) and analyzed for asbestos, MMVF,
silica and lead. Additionally, samples were collected from the inside surfaces of the ducts within the
non-Pilot Units utilizing a modified-micro vacuum technique; these were collected in accordance
with the National Air Duct Cleaners Association ARC 2002 procedures and analyzed for Total
Particulates Not Otherwise Regulated (PNOR) following NIOSH 500 methodology.
3.H.2. Mercury Vapor Using Lumex Analyzer
On June 19, 2002, with the assistance of Dr. Clyde Johnson, Assistant Professor of Environmental
Sciences at Medgar Evers College (City University of New York), EPA measured mercury vapor
levels in the twelve residential Units, three commercial Units, and all common areas in the Study
building. All sampling was conducted under pre-cleaned conditions utilizing a Lumex RA-915+
29
CITY_21MC100_004204985
NYC-WTC_000276681
OCR can misread numbers and units. Confirm readings against the page image before using them.