Shortly after the study was initiated, the procedures for the WTC Dust Cleanup Program were
developed. Once those procedures were finalized, it was decided to include a modified Scope A
cleaning procedure developed by the WTC Dust Cleanup Program as one of the cleaning methods
in the study.
3.10 Supplemental Sampling Activities
Sampling of "Non-Study" Units
As noted previously, three commercial units located within the study building, but not part of the
initial study, were also cleaned by EPA. Pre-cleanup samples collected from two of the three
non-study commercial units (Food Exchange, Lemongrass Grill) were limited to the collection of
wipe samples from within the HVAC system ducts. Analysis of these samples included lead,
MMVF, alpha-quartz and asbestos. Pre-cleanup samples collected from the remaining non-study
commercial unit (Barber Shop) included a bulk sample of insulation material which was collected
to confirm its asbestos content. Pre-cleanup wipe samples were also collected for analysis of lead,
dioxin and PAH.
Post-cleanup area air samples were collected from the three non-study commercial units (Barber
Shop, Lemongrass Grill, and The Food Exchange). The analyses for these samples included
MMVF, asbestos, alpha-quartz, and lead. Additional air samples were collected in the
Lemongrass Grill and The Food Exchange in close proximity to the HVAC return ducts, in order
to evaluate the effectiveness of the HVAC cleaning method.*^
Post-cleanup wipe samples were collected from the inside surfaces of the HVAC ducts within two
of the three non-study units (Lemongrass Grill, The Food Exchange) and analyzed for asbestos,
MMVF, alpha-quartz and lead. Additionally, samples were collected from the inside surfaces of
the ducts within the non-study units utilizing a modified micro vacuum technique; these were
collected in accordance with the National Air Duct Cleaners Association (NADCA) ACR 2002
procedures referenced in Attachment I, and analyzed for Total Particulates Not Otherwise
Regulated (PNOR) following NIOSH 0500 methodology.
3.11 Mercu/y Vapor Using Lumex® Analyzer
On June 19, 2002, with the assistance of Dr. Clyde Johnson, Assistant Professor of Environmental
Sciences at Medgar Evers College (City University of New York), EPA measured mercury vapor
levels in the thirteen residential units, three commercial units, and all common areas in the study
building. All sampling was conducted under pre-cleaned conditions utilizing a Lumex® RA-915+
Mercury Vapor Analyzer. Measurements were performed at the breathing zone of infants and
adults (6 inches and 5 feet above the floor), using continuous, real-time monitoring and data
logging of mercury levels. Further explanation of mercury sampling activities and results are
included in Attachment K, Summary ofMercury Vapor Results Using the Lumex® Vcpor
Analyzer.