Lead 0.8um (25 mm) 10 L/min. 480 min. Gilian none
MCEF cassette Air Con-2
PAH’S 2um (37 mm) 2 L/min. 480 min. Gilian none
PTFE filter Air Con-2
followed by 150
mg, 8x110, XAD-
2 sorbent tube
Dioxins/Furans 32 mm Quartz 15 L/min. 56 hour Gilian none
filter followed by Air Con-2
polyurethane foam
(PUF)
3.E.5. Calibration and Frequency
Pump flow rates were measured before and after sample collection. Pumps were calibrated before
each use and the flow rate was confirmed following the sample period. A primary dry cell calibrator
(BIOS DC-Lite) was used to establish the flow rates of the SKC personal sampling pumps. A
GiIibrator-2 High Flow Wet Cell Calibrator was used to establish the flow rates of the AirCon-2 high
volume air samplers. Calibrating for silica, calcite, and gypsum and dioxins / furans also required
separate flow chambers. Flow rates were recorded on Air Sampling Data Sheets.
3.F. Sample Analysis and Management
3.F.I. Laboratories Utilized and Analyses Performed
Inorganic analyses were provided by EMSL Laboratories, 307 West 38th St., NY, NY. These
analyses included MMVF, silica, calcite, gypsum, lead. Total Dust, pH, Total Particulates Not
Otherwise Specified (NIOSH 0500), and asbestos via PCM, PLM, and TEM. Organic analyses were
provided by Paradigm Analytical, 2627 North Chase Parkway SE, Wilmington, NC. These analyses
included PAHs and Dioxins/Furans.
3.F.2. Sample Handling and Shipment
Samples transported to EMSL were typically picked up by an EMSL courier the day after sample
collection. A small percentage of the EMSL samples, and all of the samples transported to Paradigm
Analytical, were shipped via Federal Express. Several samples were damaged during shipment and
are so documented in Attachment 14, Reporting of Analytical Results
At the conclusion of each sampling event, chain of custody (COC) records were generated
electronically using Scribe? v2.2 software. A copy of the COC records were printed, signed, and
shipped with the samples to the lab. The only COC records not generated in this fashion were those
for the April 30, 2002 bulk sampling event, and any samples collected by WRS.
3.G. Analytical Data
28