NYC 9/11 Public Portal Document
INTERNAL REVIEW DRAFT
Post P' Cleaning Samples - There were two air samples and four wipe samples collected
after the first cleaning. The results indicate that gypsum was not detected in any sample.
Since gypsum was below the detection for all of the samples collected, there were no
additional gypsum samples collected.
Lead
Before Cleaning Samples - There were four micro vacuum samples and four wipe samples
collected. The results indicate that lead was detected in three of the four micro vacuum
samples at concentrations below the comparison value of 25 pg/ft’. Three of the four wipe
samples had detectable concentrations of lead above the primary numeric criterion of 25
pg/ft2, while the fourth sample was below the detection limit.
Post P' Cleaning Samples - There were two air samples, three micro vacuum samples and
four wipe samples collected after the first cleaning. The two air samples, all three micro
vacuum samples, and three of the four wipe samples were below the detection limit. The
fourth wipe sample was above detection limit but below the primary numeric criterion. The
results from the first cleaning indicate that the cleaning technique was effective in removing
the elevated concentrations of lead that were observed prior to the first cleaning. Since the
numeric criterion was met for lead after the first cleaning, no additional lead samples were
collected.
Alpha-Quartz
Before Cleaning Samples - There were four pre-cleaning wipe samples collected. One of the
four samples was below the detection limit and the other three samples had alpha-quartz
detected.
Post P' Cleaning Samples - There were two air samples and four wipe samples collected
after the first cleaning. All of the samples were below the detection limit. This indicates that
the cleaning method used was able to reduce the pre-cleaning concentration of alpha-quartz.
Since all of the samples were below the detection limits after the first cleaning, no additional
samples were collected for alpha-quartz.
Calcite
Before Cleaning Samples - There were four pre-cleaning wipe samples collected. All four
samples were below the detection limit.
Post Cleaning Samples - There were two air samples and four wipe samples collected
after the first cleaning. All of the samples were below the detection limit. Since all of the
samples were below the detection limits after the first cleaning, no additional samples were
collected for calcite.
32
CITY_21MC100_004204988
NYC-WTC_000276684
OCR can misread numbers and units. Confirm readings against the page image before using them.