Before Cleaning Samples - There were four pre-cleaning wipe samples collected. All four
samples were below the detection limit.
Post P' Cleaning Samples - There were two air samples and four wipe samples collected
after the first cleaning. All of the samples were below the detection limit. Since all of the
samples were below the detection limits after the first cleaning, no additional samples were
collected for cristobalite.
Tridymite
Before Cleaning Samples - There were four pre-cleaning wipe samples collected. All four
samples were below the detection limit.
Post P' Cleaning Samples - There were two air samples and four wipe samples collected
after the first cleaning. All of the samples were below the detection limit. Since all of the
samples were below the detection limits after the first cleaning, no additional samples were
collected for tridymite.
MMVF
Before Cleaning Samples - There were four pre-cleaning wipe samples collected. One of the
four samples was below the detection limit and the other three samples had MMVF detected.
Post P' Cleaning Samples - There were two air samples and five wipe samples collected
after the first cleaning. The results for the two air samples indicate that MMVF was present;
however, both samples were below the numeric criterion of 10 S/L. The results of the five
wipe samples indicate that MMVF was still present after the first cleaning; however, the
concentrations detected were lower than the pre-cleaning samples. There is not a numeric
criterion for MMVF in settled dust. Since the air samples were below the numeric criterion
and the MMVF in settled dust was reduced after the first cleaning, no additional samples
were collected for MMVF.
PAHs
Before Cleaning Samples - There were four pre-cleaning wipe samples collected. Three of
the four samples were below the detection limit and the TEF for these samples were below
the primary numeric criterion. The fourth sample had three PAH compounds detected;
however, the calculated TEF was below the numeric criterion of 300 pg/m^.
Post P' Cleaning Samples - There were four wipe samples collected after the first cleaning.
All of the samples were below the detection limit and the TEF for each sample was below the
numeric criterion of 300 pg/m’. Since all of the samples were below the detection limit and
the numeric criterion after the first cleaning, no additional samples were collected for PAHs.