Total Dust Before Cleaning Samples - There were four pre-cleanmg wipe samples collected; however, EPA only requested to have one of the samples analyzed. The results indicate that there was dust present.

Post P' Cleaning Samples - There were four wipe samples collected after the first cleaning; however, EPA only requested to have two of the samples analyzed. Both samples indicate that dust was present; however, the concentrations reported were lower than the pre-cleaning concentration. This indicates that the cleaning technique used was able to remove dust. As total dust does not have a numeric criterion and the results indicate that the concentration of dust was reduced, no additional samples were collected for total dust.

Unit 2B — This unit is a 946 sq. ft. loft with 2 separate bedrooms facing Cedar Street. The unit has hardwood floors and no carpeting. All windows were intact. All personal items except a couch were disposed of prior to cleanup. Minimal dust accumulation was present in the dwelling except for baseboard-heating elements.

Cleaning method - This unit was cleaned using test method 3A. Test method 3A used an Industrial HEPA filtered vacuum. An Air Filtration Devise was not used while cleaning this unit. In addition, all horizontal surfaces were wet wiped.

Numeric Criteria - This unit met the numeric criteria listed in Table 1 for each compound after being cleaned once.

Asbestos Before Cleaning Samples - Pre-cleaning micro vacuum and wipe samples were collected for asbestos. These samples indicate that asbestos was present in the unit prior to cleaning. Chrysotile was detected in all three micro vacuum samples and three of the four wipe samples detected chrysotile, and one of the three samples also contained Anthophyllite. However, the result for this sample, as well as the fourth wipe sample, was below the detection limit.

Post P' Cleaning - Test IB - Post-cleaning sampling consisted of collecting air, micro vacuum, and wipe samples. The three air samples were analyzed using PCM, TEM AHERA, and TEM PCMe. The PCM results were all below the secondary numeric criterion of 0.01 f/cc. All three TEM AHERA results were below the secondary numeric criteria of 0.022 S/cc. Likewise, all three TEM PCMe results were below the secondary criteria of 0.0009 S/cc.

The results for the four micro vacuum samples indicate that asbestos was present at levels similar to and in some cases higher than those observed before cleaning.

34

CITY_21MC100_004204990

NYC-WTC_000276686

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000276686Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000243565

EIA report for Law Department project at 100 Church Street by TRC.

Similar indexed content

Compare copies and versions →