Total Dust
Before Cleaning Samples - There were four pre-cleanmg wipe samples collected; however,
EPA only requested to have one of the samples analyzed. The results indicate that there was
dust present.
Post P' Cleaning Samples - There were four wipe samples collected after the first cleaning;
however, EPA only requested to have two of the samples analyzed. Both samples indicate
that dust was present; however, the concentrations reported were lower than the pre-cleaning
concentration. This indicates that the cleaning technique used was able to remove dust. As
total dust does not have a numeric criterion and the results indicate that the concentration of
dust was reduced, no additional samples were collected for total dust.
Unit 2B — This unit is a 946 sq. ft. loft with 2 separate bedrooms facing Cedar Street. The unit has
hardwood floors and no carpeting. All windows were intact. All personal items except a couch were disposed
of prior to cleanup. Minimal dust accumulation was present in the dwelling except for baseboard-heating
elements.
Cleaning method - This unit was cleaned using test method 3A. Test method 3A used an
Industrial HEPA filtered vacuum. An Air Filtration Devise was not used while cleaning this unit. In
addition, all horizontal surfaces were wet wiped.
Numeric Criteria - This unit met the numeric criteria listed in Table 1 for each compound
after being cleaned once.
Asbestos
Before Cleaning Samples - Pre-cleaning micro vacuum and wipe samples were collected for
asbestos. These samples indicate that asbestos was present in the unit prior to cleaning.
Chrysotile was detected in all three micro vacuum samples and three of the four wipe
samples detected chrysotile, and one of the three samples also contained Anthophyllite.
However, the result for this sample, as well as the fourth wipe sample, was below the
detection limit.
Post P' Cleaning - Test IB - Post-cleaning sampling consisted of collecting air, micro
vacuum, and wipe samples. The three air samples were analyzed using PCM, TEM AHERA,
and TEM PCMe. The PCM results were all below the secondary numeric criterion of 0.01
f/cc. All three TEM AHERA results were below the secondary numeric criteria of 0.022
S/cc. Likewise, all three TEM PCMe results were below the secondary criteria of 0.0009
S/cc.
The results for the four micro vacuum samples indicate that asbestos was present at levels
similar to and in some cases higher than those observed before cleaning.
34
CITY_21MC100_004204990
NYC-WTC_000276686