The results for the five wipe samples that were collected indicate that asbestos was present in
three of the five samples. Two of the two samples in which asbestos was detected were
below the detection limit.
Dioxin
Before Cleaning Samples - There were three pre-cleaning wipe samples collected and
analyzed for dioxin. The results indicate that there was dioxin present; however, the TEQ
concentrations for each sample were below the primary numeric criterion of 4 ng/mY
Post P' Cleaning Samples - There were four post-cleaning wipe samples collected and
analyzed for dioxin. The results indicate that the TEQ concentrations for each sample were
below the primary numeric criterion of 4 ng/m\
Gypsum
Before Cleaning Samples - There were three pre-cleaning wipe samples collected. The
results indicate that gypsum was not detected.
Post Cleaning Samples - There were two air samples and four wipe samples collected
after the first cleaning. The results indicate that gypsum was not detected in any sample.
Lead
Before Cleaning Samples - There were three micro vacuum samples and three wipe samples
collected. The results indicate that lead was detected in one of the three micro vacuum
samples at a concentrations below the comparison value of 25 pg/ft^. Two of the three wipe
samples had detectable concentrations of lead, with one sample being above the primary
numeric criterion of 25 pg/ft^. The third sample was below the detection limit.
Post Cleaning Samples - There were two air samples, four micro vacuum samples and
four wipe samples collected after the first cleaning. The two air samples were below the
primary numeric criterion. The four micro vacuum samples, and one of the four wipe
samples were below the detection limit. Three of the four wipe samples were above the
detection limit but below the primary numeric criterion of 25 pg/ft’. The results from the
first cleaning indicate that the cleaning technique was effective in removing the elevated
concentrations of lead that were observed prior to the first cleaning.
Post 2nd Cleaning Sampling - Since the cleaning was conducted prior to the establishment of
a risk-based cleanup level for lead in air, this unit was recleaned in an effort to meet the
previously established numeric level. The sampling results following the second cleaning
indicate that the numeric criterion was met, as the sample result was below the numeric
criterion.