NYC-WTC_000363060
Interim final report noting organizations involved and plan for third-party review.
44 shared non-person entities · 1 shared topics · similarity 0.996
machine-extracted · confidence unavailable · Check page ↗EPA NYC Region 2 WTC response document, City data file.
NYC-WTC_000431857–000432027OCR status: ok · source: pdftotext
NYC 9/11 Public Portal Document
Post P* Cleaning Samples - Four wipe samples were collected after the first cleaning. All of the samples were below the detection limit and the TEF for each sample was below the primary clearance criterion of 300 pg/m^. Because all of the samples were below the detection limit and the primary clearance criterion after the first cleaning, no additional samples were collected for analysis of PAH.
Unit 4C - This unit is located on the fourth floor. It is a 655 sq. ft. open loft that faces the WTC site. The windows were blown in and there was significant dust accumulation in the dwelling. The unit has hardwood floors and no carpet. All personal possessions to be retained by the tenant were vacuumed and bagged.
Cleaning Method - This unit was cleaned using Test 1 A: a Craftsman® shop vacuum and a Eureka® upright vacuum for vacuuming the floors and other surfaces. No HEPA or AFD was used during the cleaning process. In addition, all horizontal surfaces were wet wiped.
Cleaning Results - This unit met the clearance criteria listed in Table 1.0 for each compound after being cleaned once.
Supplemental Sampling Activities - The air samples collected for PAH analysis were taken for reference purposes only. These samples are discussed in the PAH section below.
Asbestos Before Cleaning Samples - Pre-cleaning micro vacuum and wipe samples were collected for asbestos. These samples indicate that asbestos was present in the unit prior to cleaning. All four of the micro vacuum samples detected chrysotile, and one of the four micro vacuum samples detected amosite. Three of the four wipe samples detected chrysotile; however, one of these samples was below the detection limit. The fourth wipe sample did not detect chrysotile and was below the detection limit.
Post P* Cleaning Samples - Three air samples, three micro vacuum samples, and five wipe samples were collected for asbestos. The samples were analyzed using PCM, TEM AHERA, and PCMe. The PCM analysis could not be conducted due to overloading of particulate material. The TEM AHERA results were above the detection limit but were below the secondary numeric criterion of 0.022 S/cc. Two of the three air samples analyzed using PCMe were below the primary clearance criterion of 0.0009 S/cc. The third air sample detected chrysotile and was present at the primary clearance criterion of 0.0009 S/cc. Since the primary primary clearance criterion was met, no additional cleaning was required.
The results of the three micro vacuum samples indicate that asbestos was present at levels lower than those observed before cleaning.
The results of the five wipe samples indicate that asbestos was present above the detection level in one of the five samples. The concentrations were lower than in the pre-cleaning concentrations.
64
CITY_21MC100_011132943
NYC-WTC_000431924
OCR can misread numbers and units. Confirm readings against the page image before using them.
Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.
NYC-WTC_000363060
Interim final report noting organizations involved and plan for third-party review.
44 shared non-person entities · 1 shared topics · similarity 0.996
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000195194
Document excerpt acknowledging contributors and outlining the collaborative scope of an EPA environmental protection study regarding the World Trade Center site.
45 shared non-person entities · 1 shared topics · similarity 1.000
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000145695
Form documenting the tracking and handling of environmental samples collected by the Department of Environmental Protection.
45 shared non-person entities · 1 shared topics · similarity 0.995
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000276652
Table of contents for contaminants of [name] report and building sections.
32 shared non-person entities · 1 shared topics · similarity 0.990
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000145027
Notice from NYC Law Department instructing staff to preserve World Trade Center documents for potential legal actions.
28 shared non-person entities · 1 shared topics · similarity 0.970
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000155174
Chain of custody documentation for cleanup and monitoring samples at 114 Liberty distributed among project team members.
12 shared non-person entities · 1 shared topics · similarity 0.964
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000162938
Correspondence regarding monitoring activities and documentation for the asbestos cleanup at 114 Liberty Street in early 2003.
12 shared non-person entities · 1 shared topics · similarity 0.964
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000138897
Internal DEP coordination regarding comments on 114 Liberty procedures and preparation of a response.
12 shared non-person entities · 1 shared topics · similarity 0.964
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000243565
EIA report for Law Department project at 100 Church Street by TRC.
17 shared non-person entities · similarity 0.963
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000243703
Environmental assessment prepared for NYC Law Department by TRC Engineers, April 8, 2002.
17 shared non-person entities · similarity 0.962
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000155286
Formal letter criticizing the EPA and DEP for alleged failures in cleaning asbestos and silica from 114 Liberty Street.
13 shared non-person entities · similarity 0.962
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000176247
Comprehensive environmental assessment report prepared by TRC Engineers for the New York City Law Department.
17 shared non-person entities · similarity 0.962
machine-extracted · confidence unavailable · Check page ↗Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.
NYC-WTC_000145695
Form documenting the tracking and handling of environmental samples collected by the Department of Environmental Protection.
Similarity score 0.999 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000363060
Interim final report noting organizations involved and plan for third-party review.
Similarity score 0.999 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000195194
Document excerpt acknowledging contributors and outlining the collaborative scope of an EPA environmental protection study regarding the World Trade Center site.
Similarity score 0.998 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000363060
Interim final report noting organizations involved and plan for third-party review.
Similarity score 0.991 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000145695
Form documenting the tracking and handling of environmental samples collected by the Department of Environmental Protection.
Similarity score 0.990 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000195194
Document excerpt acknowledging contributors and outlining the collaborative scope of an EPA environmental protection study regarding the World Trade Center site.
Similarity score 0.990 (not a probability)
machine-extracted · confidence unavailable · Check page ↗Machine-extracted building matches; verify each source. Buildings, never households.
Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.
NYC-WTC_000195194
Document excerpt acknowledging contributors and outlining the collaborative scope of an EPA environmental protection study regarding the World Trade Center site.
Similar indexed content
NYC-WTC_000363060
Interim final report noting organizations involved and plan for third-party review.
Similar indexed content
NYC-WTC_000145695
Form documenting the tracking and handling of environmental samples collected by the Department of Environmental Protection.
Similar indexed content
NYC-WTC_000276652
Table of contents for contaminants of [name] report and building sections.
Similar indexed content
NYC-WTC_000145027
Notice from NYC Law Department instructing staff to preserve World Trade Center documents for potential legal actions.
Similar indexed content