primary clearance criterion. Since the primary clearance criterion was met for lead after the first cleaning, no additional cleaning was necessary.

Post 2’^ Cleaning Sampling - Because the cleaning was conducted prior to the establishment of a risk based cleanup level for lead in air, this unit was re-cleaned in an effort to meet the initially established clearance criterion . Sampling results following the second cleaning indicated levels below the primary clearance criterion.

Alpha-Quartz Before Cleaning Samples - Pre-cleaning air samples were not collected.

Post P‘ Cleaning Samples - Two air samples were collected after the first cleaning. All of the samples were below the detection limit.

Calcite Before Cleaning Samples - Pre-cleaning air samples were not collected.

Post Cleaning Samples - Two air samples were collected after the first cleaning. All of the samples were below the detection limit.

Cristobalite Before Cleaning Samples - Pre-cleaning air samples were not collected.

Post Cleaning Samples - Two air samples were collected after the first cleaning. All of the samples were below the detection limit.

Tridymite Before Cleaning Samples - Pre-cleaning air samples were not collected.

Post P* Cleaning Samples - Two air samples were collected after the first cleaning. All of the samples were below the detection limit.

MMVF Before Cleaning Samples - Four pre-cleaning wipe samples collected. All four samples had MMVF detected above the detection limit.

Post P‘ Cleaning Samples - Three air samples and five wipe samples were collected after the first cleaning. The results for the three air samples indicate that MMVF was present; however, both samples were below the primary clearance criterion of 10 S/L. The results of the five wipe samples indicate that MMVF was still present after the first cleaning; however, the concentrations detected were generally lower than the pre-cleaning samples. There is not a clearance criterion for MMVF in settled dust.

PAH Before Cleaning Samples - Four pre-cleaning wipe samples were collected. All four samples were below the detection limit and the TEF for each sample was below the primary clearance criterion.

63

CITY_21MC100_011132942

NYC-WTC_000431923

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000431923Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →