primary clearance criterion. Since the primary clearance criterion was met for lead after
the first cleaning, no additional cleaning was necessary.
Post 2”‘' Cleaning Sampling - Because the cleaning was conducted prior to the
establishment of a risk based cleanup level for lead in air, this unit was re-cleaned in an
effort to meet the initially established clearance criterion . Sampling results following the
second cleaning indicated levels below the primary clearance criterion.
Alpha-Quartz
Before Cleaning Samples - Pre-cleaning air samples were not collected.
Post Cleaning Samples - Two air samples were collected after the first cleaning. All of
the samples were below the detection limit.
Calcite
Before Cleaning Samples - Pre-cleaning air samples were not collected.
Post Cleaning Samples - Two air samples were collected after the first cleaning. All of
the samples were below the detection limit.
Cristobalite
Before Cleaning Samples - Pre-cleaning air samples were not collected.
Post P‘ Cleaning Samples - Two air samples were collected after the first cleaning. All of
the samples were below the detection limit.
Tridymite
Before Cleaning Samples - Pre-cleaning air samples were not collected.
Post P‘ Cleaning Samples - Two air samples were collected after the first cleaning. All of
the samples were below the detection limit.
MMVF
Before Cleaning Samples - Four pre-cleaning wipe samples collected. AU four samples
had MMVF detected above the detection limit.
Post Cleaning Samples - Three air samples and five wipe samples were collected after
the first cleaning. The results for the three air samples indicate that MMVF was present;
however, both samples were below the primary clearance criterion of 10 SZL. The results
of the five wipe samples indicate that MMVF was still present after the first cleaning;
however, the concentrations detected were generally lower than the pre-cleaning samples.
There is not a clearance criterion for MMVF in settled dust.
PAH
Before Cleaning Samples - Four pre-cleaning wipe samples were collected. AU four
samples were below the detection limit and the TEF for each sample was below the
primary clearance criterion.