Post P* Cleaning Samples - Two air samples, three micro vacuum samples and four wipe samples were collected after the first cleaning. The two air samples, all three micro vacuum samples, and three of the four wipe samples were below the detection limit. The fourth wipe sample was above detection limit but below the primary clearance criterion. The results from the first cleaning indicate that the cleaning technique was effective in removing the elevated concentrations of lead observed prior to the first cleaning. Because the primary clearance criterion for lead was met after the first cleaning, no additional samples were collected for analysis of lead.

Alpha-Quartz Before Cleaning Samples - Pre-cleaning air samples were not collected.

Post P* Cleaning Samples - Two air samples were collected after the first cleaning. All of the samples were below the detection limit. This indicates that the cleaning method used was able to reduce the pre-cleaning concentration of alpha-quartz. Because all of the samples were below the detection limit after the first cleaning, no additional samples were collected for analysis of alpha-quartz.

Calcite Before Cleaning Samples - Pre-cleaning air samples were not collected.

Post P‘ Cleaning Samples - Two air samples were collected after the first cleaning. All of the samples were below the detection limit. Because all of the samples were below the detection limit after the first cleaning, no additional samples were collected for analysis of calcite.

Cristobalite Before Cleaning Samples - Pre-cleaning air samples were not collected.

Post P* Cleaning Samples - Two air samples were collected after the first cleaning. All of the samples were below the detection limit. Because all of the samples were below the detection limits after the first cleaning, no additional samples were collected for analysis of cristobalite.

Tridymite Before Cleaning Samples - Pre-cleaning air samples were not collected.

Post P* Cleaning Samples - Two air samples were collected after the first cleaning. All of the samples were below the detection limit. Because all of the samples were below the detection limits after the first cleaning, no additional samples were collected for analysis of tridymite.

MMVF Before Cleaning Samples - Four pre-cleaning wipe samples were collected. One of the four samples was below the detection limit; MMVF was detected in the other three samples.

40

CITY_21MC100_011132919

NYC-WTC_000431900

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000431900Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →