six of the micro vacuum samples detected chrysotile above the detection limit. Two of the
five wipe samples were below the detection limit, although one detected chrysotile. The
remaining three samples were above the detection limit.
Post J"' Cleaning Samples - Post-cleaning micro vacuum, wipe and air samples were
collected for asbestos. The samples were analyzed using PCM, TEM AHERA, and PCMe.
The results for the PCM analysis indicate that two of the three samples were below the
secondary numeric criterion of 0.01 f/cc. The third slightly exceeded this value with a
concentration of 0.02 f/cc. The TEM AHERA results indicate that all three samples were
below the secondary numeric criterion of 0.022 s/cc. The PCMe results indicate that two of
the three air samples were below the primary numeric criterion of 0.0009 S/cc. The third
sample detected chrysotile and was at the numeric criterion of 0.0009 S/cc.
The results of the six micro vacuum samples indicate that asbestos was present at levels
lower than those observed before cleaning.
The results of the five wipe samples indicate that asbestos was present in all of the samples at
concentrations similar or lower to those observed before cleaning.
Dioxin
Before Cleaning Samples - There were four pre-cleaning wipe samples collected and
analyzed for dioxin. The results indicate that there was dioxin present; however, the TEQ
concentrations for each sample were below the numeric criterion of 4 ng/nr.
Post Cleaning Samples - There were four post-cleaning wipe samples collected and
analyzed for dioxin. The results indicate that there was dioxin present at concentrations
lower than those observed in the pre-cleaning samples. In addition, the TEQ concentration
for each sample was below the numeric criterion of 4 ng/m'. This indicates the cleaning
techniques were effective at reducing dioxin concentrations.
Gypsum
Before Cleaning Samples - There were four pre-cleaning wipe samples collected. The results
indicate gypsum was not detected above the detection limit range of 20 to 80 mg/m\
Post P' Cleaning Samples - There were two air samples and four wipe samples collected after
the first cleaning. The results indicate that gypsum was not detected above the detection limit
of 0.016 mg/m^ for the air samples, and not detected above the detection limit of 40 mg/m^
for wipe samples.
Lead
Before Cleaning Samples - There were six micro vacuum samples and four wipe samples
collected. The results indicate that lead was detected in all six of the micro vacuum samples
67