Post P' Cleaning Samples - There were three air samples and five wipe samples collected
after the first cleaning. All of the air sample results indicate that MMVF was present but at
concentrations below the numeric criterion of 10 S/L. The wipe sample results were detected
in a concentrations ranging from 57.23 S/cc to 343.39 S/cc, which were similar to or lower
than the pre-cleaning samples.
PAHs
Before Cleaning Samples - There were three pre-cleaning wipe samples collected. Two of the
three samples were below the detection limit and the TEF for each sample was below the
numeric criterion. The third had one PAH compound detected; however the calculated TEF
was below the primary numeric criterion of 300 pg/m^.
Post P' Cleaning Samples - There were two post-cleaning air samples and four post-cleaning
wipe samples collected. Both air samples had seven PAH compounds detected; however, the
calculated TEFs for these samples were below the numeric criterion of 0.2 pg/mf All wipe
samples were below the detection limit and the TEF for each sample was below the numeric
criterion of 300 pg'nf.
Total Dust
Before Cleaning Samples - There were three pre-cleaning wipe samples collected; however,
EPA only requested to have one of the samples analyzed. The results indicate that dust was
present at 2,020,000 pg/mf
Post 1" Cleaning Samples - There were four post-cleaning wipe samples collected; however,
EPA only requested to have two of the samples analyzed. Both samples indicate that dust
was present at concentrations lower than the pre-cleaning concentrations.
Unit 4D - This is a 968 sq. ft. open loft facing the World Trade Center site. The unit had windows
blown-in and contained significant accumulation of dust. The dwelling has hardwood floors with no
carpet. All personal possessions to be retained by the tenant were vacuumed and bagged.
Cleaning Method - This unit was cleaned using test method 2A. Test method 2A used a
Ridgid shop vacuum and a Eureka upright with a HEPA filter. No air filtration devices
(AFD) were used. All horizontal surfaces were wet wiped. This cleaning method was used
for each cleaning event.
Numeric Criteria - This Unit met the numeric criteria listed in Table 1 for each compound
after being cleaned twice.
Asbestos
Before cleaning samples - Pre-cleaning micro vacuum and wipe samples were collected for
asbestos. These samples indicate that asbestos was present in the unit prior to cleaning. All