and determined to be invalid due to an equipment malfunction which resulted in the collection of a volume of air significantly lower than the other four samples. It should be noted that the other four post-2nd cleaning air samples, and the three post-1st cleaning air samples were below the applicable health-based benchmark.

PAH Before Cleaning Scanpies - Three pre-cleaning wipe samples were coUected. Two of the three samples were below the detection limit. The calculated TEF for these two samples was below the primary clearance criterion. Twelve PAH compounds were detected in the third sample. The calculated TEF for this sample exceeded the TEF of 300 gg/m^ with a value of 1,046.6 pg/m^.

Post P‘ Cleaning Samples - Four post-cleaning wipe samples were coUected. All four samples were below the detection limit. The TEF for each sample was below the primary clearance criterion of 300 pg/m^. This indicates that the cleaning techniques used were effective in reducing the PAH pre-cleaning concentrations.

Unit 3D - This unit is located on the third floor. It is a 968 sq. fl. loft with three bedrooms, facing the WTC site. The unit has hardwood floors with no carpet. This unit presented a significant accumulation of dust in the dwelling. Its windows were blown in. The majority of personal items, with the exception of three pieces of hardwood furniture, were disposed of prior to cleaning.

Cleaning Method - This unit was cleaned using Test 1 A: a Ridgid® shop vacuum and a Hoover® upright without a HEP A filter. AFDs were not used during cleaning. All horizontal surfaces were wet wiped. This cleaning method was used for each cleaning event.

deeming Results - This unit met the clearance criteria listed in Table 1.0 for each compound after being cleaned twice.

Asbestos Before Cleaning Samples - Three micro vacuum and five wipe samples were collected for asbestos. These samples indicate that asbestos was present in the unit before cleaning. AU three of the micro vacuum samples detected chrysotile, and four of the five wipe samples detected chrysotile. The remaining sample was below the detection limit.

Post Cleaning Samples - Three micro vacuum, five wipe samples and three air samples were collected for asbestos.

All three of the air samples, which were analyzed using PCM, TEM AHERA, and PCMe, could not be analyzed due to overloading of particulate material. Due to this situation, a second cleaning was conducted.

The results of the three micro vacuum samples indicate that asbestos was present at levels lower than those observed before cleaning. One of the samples was below the detection limit.

54

NYC-WTC_000145752

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000145752Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Page similarity is temporarily unavailable or this page has no indexed vector.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000136990

Archival folder label for September 11 news clippings from the Office of the Mayor, identified as Folder 0123.

Cited alongside this record in an Ask answer

NYC-WTC_000153313 · Box DEP Box 26

Updated memorandum defining the Red Zone boundaries and listing authorized agencies for entry into the restricted area.

Cited alongside this record in an Ask answer

NYC-WTC_000149744 · Box DEP Box 10

Policy document outlining NYPD access requirements for building owners and contractors at the site in October 2001.

Cited alongside this record in an Ask answer

Compare copies and versions →