INTERNAL REVIEW DRAFT

analyzed for lead. The result for this sample indicates that the concentration was below the primary numeric criterion of 1 pg/m'.

Alpha Quartz Before Cleaning Samples - There were three pre-cleaning wipe samples collected. One of the three samples was below the detection limit and the other samples had alpha-quartz detected.

Post J'' Cleaning Samples - There were two air and four wipe samples collected after the first cleaning. All samples were below the detection limit except one wipe sample which was not analyzed because filter material was not available.

Calcite Before Cleaning Samples - There were three pre-cleaning wipe samples collected. Two of the three samples were below the detection limit while the fourth was above the detection limit.

Post P‘ Cleaning Samples - There were two air samples and four wipe samples collected after the first cleaning. All of the samples were below the detection limit, with the exception of one sample that was not analyzed because filter material was not available.

Cristobalite Before Cleaning Samples - There were three pre-cleaning wipe samples collected. Ail four samples were below the detection limit.

Post P' Cleaning Samples - There were two air samples and four wipe samples collected after the first cleaning. All of the samples were below the detection limit, with the exception of one sample that was not analyzed because filter material was not available.

Tridymite Before Cleaning Samples - There were three pre-cleaning wipe samples collected. All four samples were below the detection limit.

Post P' Cleaning Samples - There were two air samples and four wipe samples collected after the first cleaning. All of the samples were below the detection limit, with the exception of one sample that was not analyzed because filter material was not available.

MMVF Before Cleaning Samples - There were three pre-cleaning wipe samples collected. The three wipe samples had MMVF detected at concentrations from 57.23 S/cc to 1030.17 S/cc. This indicates MMVF was present prior to cleaning.

65

CITY_21MC100_0 04205021

NYC-WTC_000276717

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000276717Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000243565

EIA report for Law Department project at 100 Church Street by TRC.

Similar indexed content

Compare copies and versions →