Post J'' Cleaning Samples, Test 4C - Post-cleaning air and micro vacuum samples
were collected for asbestos. The air samples were analyzed for PCM, TEM AHERA,
and PCMe. The PCM analysis could not be conducted due to overloading of the filter
with particulate matter. The TEM AHERA results indicate that three of the five
samples could not be analyzed due to overloading of the filters with particulate
material. The remaining two samples were below the secondary numeric criterion of
0.022 S/cc. The TEM PCMe results indicate that three of the five air samples
analyzed could not be analyzed due to overloading of particulate matter. The
remaining two PCMe results indicate that one sample was below the numeric criteria
and one sample exceeded the numeric criteria of 0.0009 S/cc at 0.0033 S/cc.
The results of the four micro vacuum samples indicate that asbestos was present in all
five samples at lower concentrations than those obseiwed before cleaning but at
similar concentrations to those after the test 4A cleaning.
Post P' Cleaning Samples, Test 4D - Post-cleaning air samples were collected for
asbestos. The samples were analyzed for PCM, TEM AHERA, and TEM PCMe.
The PCM results indicate that all three samples were below the secondary numeric
criterion of 0.01 f/cc. The TEM AHERA results indicate that all three samples were
below the. detection limit and below the secondary numeric criterion of 0.022 S/cc.
The TEM PCMe results were all below the detection limit and were below the
primary numeric criteria of 0.0009 S/cc.
Dioxin
Before Cleaning Samples - There were pre-cleaning air and wipe samples collected
and analyzed for dioxin. The results indicate that there was dioxin present; however,
the TEQ concentration for each sample was below the numeric criterion of 4 ng/m’.
Post 1" Cleaning Samples, Test 4A - There were four post-cleaning wipe samples
collected and analyzed for dioxin. The results indicate that the TEQ concentration for
each sample was below the criterion of 4 ng/m^.
Post J" Cleaning Samples, Test 4B - There were four post-cleaning wipe samples
collected and analyzed for dioxin. The results indicate that the concentrations of
dioxin were similar to the pre-cleaning samples and the TEQ concentration for each
sample was below the criterion of 4 ng/m^'
Post P' Cleaning Samples, Test 4E - There were three post-cleaning wipe samples
collected and analyzed for dioxin. The results indicate that the concentrations of
dioxin were slightly less than the pre-cleaning samples and the TEQ concentration for
each sample was below the criterion of 4 ng/nY