NYC Law Department release
Independent mirror · updated as the City releases more · v1.5.1
☕ Buy me a coffee
← Document results/Unboxed/No folder label
Document / 121 pages

COPCS report, NYC WTC chain of custody

Machine-extracted title · confidence 50%

Table of contents for contaminants of [name] report and building sections.

NYC-WTC_000276652–000276772
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

INTERNAL REVIEW DRAFT

Gypsum Before Cleaning Samples - There were four pre-cleaning wipe samples collected. The results indicate gypsum was not detected above the detection limit of 40 mg/m^.

Post P' Cleaning Samples, Test 4A - There were two air and four wipe samples collected. Sampling results indicate that gypsum was not detected in air above the detection limit range of 0.008 mg/m^ to 0.017 mg/m^ or in the wipe samples above the detection limit of 10 rng nr.

Post Cleaning Samples, Test 4B - There were two air and four wipe samples collected. Sampling results indicate that gypsum was detected in air at concentrations of 0.011 mg/m’ and 0.014 mg/m\ Gypsum was not detected in the wipe samples above the detection limit of 10 mg/m^.

Post J" Cleaning Samples, Test 4C - There were two air samples collected. Sampling results indicate that gypsum was detected in air above the detection limit with the results of 0.009 mg/m^ to 0.012 mg/m\

Lead Before Cleaning Samples - There were four micro vacuum samples and four wipe samples collected. The results indicate that lead was detected in all of the micro vacuum samples and wipe samples collected. Three of the four micro vacuum results exceeded the comparison value of 25 pg/ft^, ranging from 7.22 pg/ft' tol81 pg/ft^. Wipe sample concentrations exceeded the primary numeric criterion of 25 pg/lV in all of the samples ranging in concentrations from 74.7 pg/ff to 433 pg/fV.

Post P' Cleaning Samples, Test 4A - There were two air samples, four micro vacuum samples, and four wipe samples collected after the first cleaning. The two air samples were below the numeric criterion of 1 pg/m\ The results of the micro vacuum and wipe samples show that, while all of the micro vacuum and two of the wipes samples were below the comparison value or primary numeric criterion, the remaining two wipe samples exceeded the primary numeric criterion with concentrations of 64.5 pg/tf and 146 pg/ff.

Post Cleaning Samples, Test 4B - There were two air samples and four wipe samples collected. The two air samples were below the numeric criteria of 1 pg/m\ Two of the four wipe samples exceeded the primary numeric criterion at concentrations of 147 pg/ft" and 556 pg/ft\

Post J" Cleaning Samples, Test 4C - There were two air samples and four micro vacuum samples collected. The two air samples both exceeded the numeric criterion

91

CITY_21MC100_004205047

NYC-WTC_000276743

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000276743Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000243565

EIA report for Law Department project at 100 Church Street by TRC.

Similar indexed content

Compare copies and versions →