Post P' Cleaning Samples - There were two samples collected after the first cleaning, and both were below the detection limit.

Tridymite Before Cleaning Samples - There were no before cleaning samples collected.

Post J"' Cleaning Samples - There were two samples collected after the first cleaning, and both were below the detection limit.

MMVF Before Cleaning Samples - There were no before cleaning samples collected.

Post Cleaning Samples - There were two samples collected after the first cleaning and the results indicate that MMVF was only present in one sample. Both samples were below the numeric criterion of 10 S/L.

Commercial Unit: Chiropractor Office - This is a 716 sq. ft. office space with 4 examination rooms facing the World Trade Center site. All front windows were blown-in and excessive amounts of dust was present on all horizontal and vertical surfaces. Floor areas were covered with wall to wall carpeting, the suspended ceiling was covered with fibrous tiles, and there was a two foot high void space above the ceiling. Ceiling tiles were removed and disposed prior to cleaning, as well as flexible ventilation ducts and office equipment. The space above the suspended ceiling contained the HVAC system and wood floor joist system for the 3"* floor apartment. This area contained WTC-related and non- WTC- related dust. The space was extremely difficult to clean due to the presence of electrical wires, recessed lighting fixtures, sprinkler systems, and the dry, friable nature of the wood support system.

Cleaning Method - This unit was subject to separate tests to evaluate 5 different cleaning techniques as described below:

Test 4A: Industrial HEPA filtered vacuums and AFD. Test 4B: Wet wipe all walls. Test 4C: Hot water wet vacuum Test 4D: A/C Duct Cleaning Test 4E: Water “only” wet wipe of bathroom floor and desk top.

Numeric Criteria - This unit met the numeric criteria listed in Table 1 for each compound after being cleaned once for each of the five different cleaning techniques.

Supplemental Sampling Activities - Prior to initiating pre-cleanup sampling activities as described below, EPA collected a bulk composite sample from the Chiropractor

88

CITY_21MC100_004205044

NYC-WTC_000276740

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000276740Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000243565

EIA report for Law Department project at 100 Church Street by TRC.

Similar indexed content

Compare copies and versions →