INTERNAL REVIEW DRAFT

Numeric Criteria - This unit met the numeric criteria listed in Table 1 for each compound after being cleaned once.

Asbestos Before Cleaning Samples - There were no before cleaning samples collected.

Post P' Cleaning Samples - There were two post-cleaning air samples collected. The air samples were analyzed using PCM, TEM AHERA, and TEM PCMe. The PCM results were below the secondary numeric criterion of 0.01 f/cc. The TEM AHERA results indicate that chrysotile was present but both samples were below the secondary numeric criterion of 0.022 S/cc. The TEM PCMe results indicate that one sample was below the detection limit and the other had chrysotile present but at a concentration below the primary numeric criteria of 0.0009 S/cc.

Gypsum Before Cleaning Samples - There were no before cleaning samples collected.

Post Cleaning Samples - There were two air samples collected after the first cleaning. The results indicate that gypsum was not detected in either sample.

Lead Before Cleaning Samples - There were no before cleaning samples collected.

Post L‘ Cleaning Samples - There were two air samples collected after the first cleaning. Lead was not detected in either sample and the results were below the primary numeric criterion of 1 pg/m\ Since the numeric criterion was met for lead after the first cleaning, no additional lead samples were collected.

Alpha-Quartz Before Cleaning Samples - There were no before cleaning samples collected.

Post P' Cleaning Samples - There were two air samples collected after the first cleaning. Both samples were below the detection limit.

Calcite Before Cleaning Samples - There were no before cleaning samples collected.

Post P‘ Cleaning Samples - There were two samples collected after the first cleaning, and both were below the detection limit.

Cristobalite Before Cleaning Samples - There were no before cleaning samples collected.

87

CITY_21MC100_004205043

NYC-WTC_000276739

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000276739Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000243565

EIA report for Law Department project at 100 Church Street by TRC.

Similar indexed content

Compare copies and versions →