Post Cleaning Samples - There were four post-cleaning wipe samples collected and
analyzed for dioxin. The results indicate that the concentrations of dioxin detected
were slightly lower than the pre-cleaning samples and the TEQ concentration for each
sample was below the criterion of 4 iig/nf.
Lead
Before Cleaning Samples - There were four’ pre-cleaning wipe samples collected.
Three of the four samples were above the detection limit and two were above the
primary numeric criterion of 25 pg/tf. Two of these samples were qualified as
rejected due to field blank contamination. The fourth sample was below the detection
limit.
Post P' Cleaning Samples - There were two air samples and four wipe samples
collected after the first cleaning. All of the air and wipe samples were below the
detection limit and met the primary numeric air or wipe criteria for lead after the first
cleaning.
MMVF
Before Cleaning Samples - No pre-cleaning samples were collected for MMVF.
Post P' Cleaning Samples - There were three air samples collected after the first
cleaning. The results indicate that MMVF was detected in two of three samples, but
at levels below the primary numeric criterion of 10 S/L.
PAHs
Before Cleaning Samples - There were four pre-cleaning wipe samples collected.
Three of the four samples were below the detection limit and the TEF for each sample
was below the primary numeric criterion. The fourth sample detected one PAH
compound; however, the TEF was below the numeric criterion of 300 gg/nf.
Post Cleaning Samples - There were four post-cleaning wipe samples collected.
All four samples were below the detection limit, and the TEF for each sample was
below the numeric criterion of 300 p.g/m\
Cedar Street Staircase - This area consisted of wood steps/landings, sheetrock walls and
ceiling. Flooring was covered with vinyl tiles and walls and ceilings covered with gloss paint.
Cleaning method - This area was cleaned using test method 4A and test method 4B.
Test method 4A used an industrial HEPA filtered vacuum and an air filtration device.
Test method 4B consisted of a soap and water wet wipe of all horizontal and vertical
surfaces.