Commercial Unit: The Barber Shop - This 1,268 sq. ft. open space facing the World Trade
Center Site is located below grade to Liberty Street. The front door of the business was
blown inward depositing significant amounts of dust and debris down the staircase into the
rental space. Floor areas are covered with ceramic tiles; the ceiling is a suspended system
using fibrous tiles. Above the suspended ceiling is a void space which accommodates
flexible A/C ducts, electrical conduit and lights. All structural support members above the
ceiling are encapsulated with a non-asbestos insulating material. Equipment including chairs,
wash sinks, counters and hair care displays were located in the shop. The head space above
the entrance door houses an A/C condenser/compressor unit that was heavily impacted with
WTC-related dust and debris. Ceiling tiles, flexible duct, chairs, display shelving and hair
care merchandise were disposed of prior to cleaning. Adjacent to the shop space were
ancillary rooms that extend under Liberty Street. These rooms have earthen floors and are
believed to be associated with utility companies. They were not cleaned.
Cleaning Method - This unit was cleaned using test method 4A and test method 4E.
Test method 4A used industrial HEPA vacuums for vacuuming the floors and other
surfaces. An air filtration device (AFD) was used during the cleaning process. Test
method 4E used water to wet wipe all horizontal and vertical surfaces.
Numeric Criteria - This unit met the numeric criteria listed in Table 1 for each
compound after being cleaned once.
Supplemental Sampling Activities - One bulk sample of insulation material was
collected to determine its asbestos content in order to address applicable health and
safety concerns.
Asbestos
Before cleaning samples - Other than the bulk sample mentioned in the previous
section, no other pre-cleanup samples were collected.
Post P' Cleaning Samples - Post-cleaning air samples were collected for asbestos.
The samples were analyzed using PCM, TEM AHERA, and TEM PCMe. The PCM
results indicate that all three samples were below the detection limit and below the
secondary numeric criterion of 0.01 f/cc. The TEM AHERA results indicate that all
three samples were below the detection limit and below the secondary numeric
criterion of 0.022 s/cc. The PCMe results also indicate that all three samples were
below the detection limit and were below the primary numeric criteria of 0.0009 S/cc.
Dioxin
Before Cleaning Samples - There were four pre-cleaning wipe samples collected and
analyzed for dioxin. The results indicate that there was dioxin present; however, the
TEQ concentration for each sample was below the numeric criterion of 4 ng/m^.