NYC 9/11 Public Portal Document
HEPA filtered vacuum and an AFD. Test 4B was a soap and water wet wipe of the ceiling and
floor only.
Cleaning Results - This unit met the clearance criteria listed in Table 1.0 for each compound after
being cleaned once.
Asbestos
Before Cleaning Samples - There were no pre-cleaning samples collected.
Post Cleaning Samples - Two post-cleaning air samples were collected. The two air
samples were analyzed using PCM, TEM AHERA, and PCMe. The PCM results were all
below the secondary numeric criterion of 0.01 ficc. Similarly, the TEM AHERA results
were all below the secondary numeric criterion of 0.022 S/cc. The PCMe results were aU
below the primary clearance criterion of 0.0009 S/cc with one of the two samples being
below the detection limit.
Dioxin
Before Cleaning Samples - There were no pre-cleaning samples collected.
Post Cleaning Samples - There were no post-cleaning samples collected
Gypsum
Before Cleaning Samples - There were no pre-cleaning samples collected.
Post Cleaning Samples - Two air samples were collected after the first cleaning.
Gypsum was not detected in any sample.
Lead
Before Cleaning Samples - There were no pre-cleaning samples collected.
Post P‘ Cleaning Samples - Two air samples were collected after the first cleaning. The
two air samples were below the detection limit.
Alpha-Quartz
Before Cleaning Samples - There were no pre-cleaning samples collected.
Post Cleaning Samples - Two air samples were collected after the first cleaning. AU of
the samples were below the detection limit.
Calcite
Before Cleaning Samples - There were no pre-cleaning samples collected.
Post Cleaning Samples - Two air samples were collected after the first cleaning. Both
were below the detection limit.
Cristobalite
Before Cleaning Samples - There were no pre-cleaning samples collected.
44