Cleaning Method - This unit was cleaned using Test 2 A; a Ridgid® shop vacuum and a Eureka® w upright vacuum with a HEPA filter. No AFDs were used. All horizontal surfaces were wet- w wiped. This cleaning method was used for each cleaning event.

Cleaning Results - This unit met the clearance listed in Table 1.0 for each compound after being cleaned twice.

Asbestos Before Cleaning Samples - Six micro vacuum and five wipe samples were collected for asbestos. These samples indicate that asbestos was present in the unit prior to cleaning. All six of the micro vacuum samples detected chrysotile above the detection limit. Two of w the five wipe samples were below the detection limit, although one detected chrysotile. w The remaining three samples were above the detection limit.

Post P* Cleaning Samples - Three air, six micro vacuum samples and five wipe samples were collected for asbestos. The samples were analyzed using PCM, TEM AHERA, and w PCMe. The results for the PCM analysis indicate that two of the three samples were * below the secondary numeric criterion of 0.01 f/cc. The third slightly exceeded this value « with a concentration of 0.02 fee. The TEM AHERA results indicate that all three «r samples were below the secondary numeric criterion of 0.022 S/cc. The PCMe results indicate that two of the three air samples were below the primary clearance criterion of 0.0009 S/cc. The third sample detected chrysotile and was at the primary clearance criterion of 0.0009 S/cc.

The results of the six micro vacuum samples indicate that asbestos was present at levels lower than those observed before cleaning.

The results of the five wipe samples indicate that asbestos was present in all of the samples at concentrations similar to or lower than those observed before cleaning.

Diojfin Before Cleaning Samples - Four pre-cleaning wipe samples were collected and analyzed for dioxin. The results indicate that dioxin was present; however, the TEQ concentration for each sample was below the primary clearance criterion of 4 ng/m\ •< Post P* Cleaning Samples - Four post-cleaning wipe samples were collected and analyzed for dioxin. The results indicate that there was dioxin present at concentrations lower than those observed in the pre-cleaning samples. In addition, the TEQ concentration for each sample was below the primary clearance criterion of 4 ng/m^. This indicates that the cleaning techniques were effective at reducing dioxin concentrations.

w Gypsum w Before Cleaning Samples - Pre-cleaning air samples were not collected. W Post P‘ Cleaning Samples - Two air samples were collected after the first cleaning. Gypsum was not detected above the detection limit of 0.016 mg/m’ for these samples.

67

CITY_21MC100_011105297

NYC-WTC_000195263

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000195263Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

No available related records indexed in this group.

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →