Post Cleaning - Four air samples were collected for asbestos. The samples could not
be analyzed due to overloading of particulate matter on the filters. Therefore, a third
cleaning was conducted using a more aggressive cleaning method: a commercial HEPA
vacuum and an AFD.
Post Cleaning - Six air samples were collected for asbestos after the third cleaning.
The samples were analyzed for PCM, TEM AHERA, and PCMe. The results of the PCM
analysis indicate that three of the six samples were belov' the detection limit. The
remaining three samples were above the detection limit but below the secondary numeric
criterion of 0.01 ficc. The TEM AHERA results indicate that all six samples were below
the detection limit. The PCMe results also indicate that all six samples were below the
detection limit. This suggests that the cleaning techniques used for the third cleaning were
effective at reducing the particulate matter to levels that permitted valid air samples to be
collected and analyzed, with the results indicating that all six samples were below the
primary clearance criterion of 0.0009 S/cc.
Dioxin
Before Cleaning Samples - Three pre-cleaning wipe samples were collected and analyzed
for dioxin. The results indicate that dioxin was present find that the TEQ concentration
for one of the three samples was above the primary clear ance criterion of 4 ng/m^.
Post Cleaning Samples - Four post-cleaning samples were collected and analyzed for
dioxin. The results indicate that dioxin was present; hov/ever, the TEQ concentrations
were below the primary clearance criterion of 4 ng/m^. This indicates that the cleaning
techniques used were effective at reducing the pre-cleaning concentrations of dioxin.
Gypsum
Before Cleaning Samples - Pre-cleaning air samples were not collected.
Post P‘ Cleaning Samples - Two air samples were collected after the first cleaning.
Gypsum was not detected above the detection limit in the air samples.
Lead
Before Cleaning Samples - Four micro vacuum samples and three wipe samples were
collected. Lead was detected in all four micro vacuum samples at concentrations above
the comparison value. Two of the three wipe samples d etected concentrations above the
primary clearance criterion of 25 pg/ft^. The micro vacuum samples exceeded the
comparison value in a range of 39.4 pg/ft^ to 135 pg/ft^ and the two wipe samples
exceeded the primary clearance criterion at 48.7 pg/ft^ and 750 pg/ft^. This indicates that
lead was present prior to cleaning.
Post Cleaning Samples - Two air samples, four micro vacuum samples, and four wipe
samples were collected after the first cleaning. The two air samples were below the
primary clearance criterion. The results of the micro vacuum and wipe samples show that
all but one micro vacuum sample (26.9 pg/ft^) met the comparison value or primary
clearance criterion for lead.
52