NYC Law Department release
Independent mirror · updated as the City releases more · v1.3.2
☕ Buy me a coffee
← Document results/Unboxed/No folder label
Document / 173 pages

NYC-WTC_000195194

Label derived from the City's folder field. The City does not supply document titles.NYC-WTC_000195194–000195366
Page image
Scanned page image, NYC-WTC_000195264
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

Lead Before Cleaning Samples - Six micro vacuum samples and four wipe samples were collected. The results indicate that lead was detected in all six of the micro vacuum samples at concentrations above the comparison value of 25 pg/ft^ ranging from 26.2 pg/ft^ to 83.5 pg/ft^. One of the four wipe samples exceeded the primary clearance criterion of 25 pg/ft^ with a concentration of 169 pg/ft^.

Post P‘ Cleaning Samples - Two air samples, six micro vacuum samples, and four wipe samples were collected after the first cleaning. The two air samples were below the primary clearance criterion but were qualified as rejected due to lab blank contamination. The results of the micro vacuum and wipe samples show that all but one wipe sample (66 pg/ft^) met the comparison value or primary clearance criterion for lead.

Post 2"“^ Cleaning Samples - One air sample and one wipe sample were collected after the second cleaning. Both sample results were below their respective clearance criterion.

Alpha-Quartz Before Cleaning Samples - Pre-cleaning air samples were not collected.

Post P‘ Cleaning Samples - Two air samples were collected after the first cleaning. All samples were below the detection limit.

Cdcite Before Cleaning Samples - Pre-cleaning air samples were not collected.

Post P' Cleaning Samples - Two air samples were collected after the first cleaning. All of the samples were below the detection limit. Since all of the samples were below the detection limit after the first cleaning, no additional samples were collected for analysis of calcite.

Cristobalite Before Cleaning Samples - Pre-cleaning air samples were not collected.

Post Cleaning Samples - Two air samples were collected after the first cleaning. All of the samples were below the detection limit. Because all of the samples were below the detection limit after the first cleaning, no additional samples were collected for analysis of cristobalite.

Tridymite Before Cleaning Samples - Pre-cleaning air samples were not collected.

Post Cleaning Samples - Two air samples were collected after the first cleaning. All of the samples were below the detection limit. Because all of the samples were below the detection limit after the first cleaning, no additional samples were collected for analysis of tridymite.

68

CITY_21MC100_011105298

NYC-WTC_000195264

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000195264Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

No available related records indexed in this group.

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →