criteria of 0.0009 S/cc, with all three of the samples being below the detection limit. This
indicates that the cleaning techniques used were able to reduce the particulate matter in the
unit after the second cleaning, which permitted samples to be analyzed, with the results of the
analysis indicating that asbestos concentrations were below the primary numeric criterion of
0.0009 f/cc.
Dioxin
Before Cleaning Samples - There were three pre-cleaning wipe samples collected and
analyzed for dioxin. The results indicate that there was dioxin present; however, the TEQ
concentrations for each sample were below the primary numeric criterion of 4 ng/m^.
Post P’ Cleaning Samples - There were four post-cleaning wipe samples collected and
analyzed for dioxin. The results indicate that TEQ concentrations for each sample were
below the primary numeric criterion of 4 ng/m2.
Gypsum
Before Cleaning Samples - There were three pre-cleaning wipe samples collected. The
results indicate that gypsum was not detected.
Post P' Cleaning Samples - There were two air samples and four wipe samples collected
after the first cleaning. The results indicate that gypsum was not detected in any sample.
Post 2"^ Cleaning Samples - There were two air samples collected after the second cleaning.
The results indicate that gypsum was not detected in any sample.
Lead
Before Cleaning Samples - There were three micro vacuum samples and three wipe samples
collected. The results indicate that all three of the micro vacuum samples were below the
comparison value of 25 pg/ft^ and below the detection limit. The three wipe samples had
detectable concentrations of lead; however, all of the concentrations were below the primary
numeric criterion of 25 pg/ft\
Post P‘ Cleaning Samples - There were two air samples, three micro vacuum samples and
four wipe samples collected after the first cleaning. The two air samples were below the
primary numeric criterion of 1 pg/m\ Two of the three micro vacuum samples were below
the detection limit. The third micro vacuum sample was slightly above the detection limit,
but below the comparison value. Three of the four wipe samples were below the detection
limit. The fourth sample was above the detection limit but below the primary numeric
criterion. Since the numeric criterion was met for lead after the first cleaning, no additional
lead samples were collected.