NYC-WTC_000431857
EPA NYC Region 2 WTC response document, City data file.
44 shared non-person entities · 1 shared topics · similarity 0.996
machine-extracted · confidence unavailable · Check page ↗Interim final report noting organizations involved and plan for third-party review.
NYC-WTC_000363060–000363182OCR status: ok · source: pdftotext
NYC 9/11 Public Portal Document
detection limits and below the primary clearance and secondary numeric criteria.
Dipjdn Before Cleaning Samples - Four pre-cleaning wipe samples were collected and analyzed for dioxin. The results indicate that there was dioxin present; however, the TEQ concentration for each sample was below the primary clearance criterion of 4 ng/m’.
Post P‘ Cleaning Samples - Four post-cleaning wipe samples were collected and analyzed for dioxin. The results indicate that the concentrations of dioxin detected were similar to the pre-cleaning samples and that the TEQ concentrations for each sample were well below the primary clearance criterion of 4 ng/m^. Because the dioxin samples were below the primary clearance criterion for all of the samples collected, no additional samples were collected for analysis of dioxin.
Gypsum Before Cleaning Samples - Pre-cleaning air samples were not collected.
Post P‘ Cleaning Samples - Two air samples were collected after the first cleaning. Gypsum was not detected in any sample. Because gypsum was below the detection limits for all of the samples collected, no additional samples were collected for analysis of gypsum.
Lead Before Cleaning Samples - Three micro vacuum samples and four wipe samples were collected. The results indicate that all three micro vacuum samples were below the detection limit and at concentrations below the comparison value of 25 pg/ft ’ Two of the four wipe samples had detectable concentrations of lead; however, they were below the primary clearance criterion of 25 pg/ft^. The third sample was below the detection limit. The fourth sample was lost at the laboratory and was not analyzed.
Post P‘ Cleaning Samples - Two air samples, three micro vacuum samples and four wipe samples were collected after the first cleaning. The two air samples were below the primary clearance criterion of 1.0 pg/m’. All three micro vacuum samples and one of the four wipe samples were below the detection limit. Two wipe samples were below the primary clearance criterion and the fourth wipe sample was above the primary clearance criterion. Due to the one lead sample being above the primary clearance criterion, as well as the asbestos samples that exceeded the primary clearance criterion, this unit was cleaned a second time.
Post 2"^ Cleaning Samples Two lead wipe samples were collected after the second cleaning in the area where the post-first cleaning lead exceedance occurred. One of the samples was received broken at the laboratory and was not analyzed. The other sample was below the detection limit and below the primary clearance criterion. The results from the second cleaning indicate that the cleaning technique was effective in removing the elevated concentration of lead that was observed after the first cleaning.
49
CITY_21MC100_011063419
NYC-WTC_000363111
OCR can misread numbers and units. Confirm readings against the page image before using them.
Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.
NYC-WTC_000431857
EPA NYC Region 2 WTC response document, City data file.
44 shared non-person entities · 1 shared topics · similarity 0.996
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000195194
Document excerpt acknowledging contributors and outlining the collaborative scope of an EPA environmental protection study regarding the World Trade Center site.
45 shared non-person entities · 1 shared topics · similarity 0.995
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000276652
Table of contents for contaminants of [name] report and building sections.
32 shared non-person entities · 1 shared topics · similarity 0.994
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000145695
Form documenting the tracking and handling of environmental samples collected by the Department of Environmental Protection.
44 shared non-person entities · 1 shared topics · similarity 0.992
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000155174
Chain of custody documentation for cleanup and monitoring samples at 114 Liberty distributed among project team members.
12 shared non-person entities · 1 shared topics · similarity 0.965
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000138897
Internal DEP coordination regarding comments on 114 Liberty procedures and preparation of a response.
12 shared non-person entities · 1 shared topics · similarity 0.964
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000155286
Formal letter criticizing the EPA and DEP for alleged failures in cleaning asbestos and silica from 114 Liberty Street.
13 shared non-person entities · similarity 0.964
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000162938
Correspondence regarding monitoring activities and documentation for the asbestos cleanup at 114 Liberty Street in early 2003.
12 shared non-person entities · 1 shared topics · similarity 0.964
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000243565
EIA report for Law Department project at 100 Church Street by TRC.
18 shared non-person entities · similarity 0.964
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000102521
EPA letter confirming that primary and secondary clearance levels for asbestos and other contaminants were met at 114 Liberty Street.
9 shared non-person entities · similarity 0.964
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000243703
Environmental assessment prepared for NYC Law Department by TRC Engineers, April 8, 2002.
18 shared non-person entities · similarity 0.964
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000243668
Environmental assessment prepared for NYC Law Department by TRC Engineers, April 8, 2002.
18 shared non-person entities · similarity 0.964
machine-extracted · confidence unavailable · Check page ↗Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.
NYC-WTC_000431857
EPA NYC Region 2 WTC response document, City data file.
Similarity score 0.998 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000145695
Form documenting the tracking and handling of environmental samples collected by the Department of Environmental Protection.
Similarity score 0.996 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000195194
Document excerpt acknowledging contributors and outlining the collaborative scope of an EPA environmental protection study regarding the World Trade Center site.
Similarity score 0.996 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000195194
Document excerpt acknowledging contributors and outlining the collaborative scope of an EPA environmental protection study regarding the World Trade Center site.
Similarity score 0.992 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000145695
Form documenting the tracking and handling of environmental samples collected by the Department of Environmental Protection.
Similarity score 0.991 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000431857
EPA NYC Region 2 WTC response document, City data file.
Similarity score 0.991 (not a probability)
machine-extracted · confidence unavailable · Check page ↗Machine-extracted building matches; verify each source. Buildings, never households.
Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.
NYC-WTC_000431857
EPA NYC Region 2 WTC response document, City data file.
Similar indexed content
NYC-WTC_000195194
Document excerpt acknowledging contributors and outlining the collaborative scope of an EPA environmental protection study regarding the World Trade Center site.
Similar indexed content
NYC-WTC_000276652
Table of contents for contaminants of [name] report and building sections.
Similar indexed content
NYC-WTC_000145695
Form documenting the tracking and handling of environmental samples collected by the Department of Environmental Protection.
Similar indexed content
NYC-WTC_000155174
Chain of custody documentation for cleanup and monitoring samples at 114 Liberty distributed among project team members.
Similar indexed content