numeric criterion and the other two could not be analyzed due to particulate overloading
of the filter. The TEM AHERA results were below the secondary numeric criterion for
two samples. The third sample could not be analyzed due to particulate overloading of the
filter. Of the three air samples analyzed using PCMe, one sample could not be analyzed
due to overloading of particulate material. The other two samples were below the primary
clearance criterion of 0.0009 S/cc.
The results of the four micro vacuum samples indicate that asbestos was present at levels
generally lower than those observed before cleaning. One of the samples was identified as
non-detect.
The results of the five wipe samples indicate that asbestos was present in all but one
sample; however, two of the samples were identified as non-detect. One of the non-detect
samples had an elevated detection limit due to the presence of non-asbestos particulate
matter.
Dioxin
Before Cleaning Samples - Three pre-cleaning wipe samples were collected and analyzed
for dioxin. The results indicate that dioxin was present; however, the TEQ concentration
for each sample was below the primary clearance criterion of 4 ng/m^.
Post deeming Samples - Four post-cleaning wipe samples were collected and analyzed
for dioxin. The results indicate that the concentrations of dioxin were similar to the pre
cleaning samples. The TEQ concentration for each sample was below the criterion of 4
ng/m^.
Gypsum
Before Cleaning Samples - Pre-cleaning air samples were not collected.
Post f Cleaning Samples - Two air samples were collected after the first cleaning.
Gypsum was not detected above the detection limit for either sample.
Le^
Before Cleaning Samples - Four micro vacuum samples and three wipe samples were
collected. Lead was not detected in any of the micro vacuum samples. One of the wipe
samples was below the detection limit and one wipe sample was below the primary
clearance criterion of 25 pg/ft^. The third wipe sample exceeded the primary clearance
criterion at 38.9 pg/ft^.
Post Cleaning Samples - Two air samples, four micro vacuum samples, and four wipe
samples were collected after the first cleaning. The two air samples were below the
primary clearance criterion but were qualified as rejected, due to field blank
contamination. The results of the micro vacuum and wipe samples show that, while two
of the micro vacuum and two of the wipe samples exceeded the detection limits, all
samples met the primary clearance criterion and the comparison values for lead after the
first cleaning.