NYC 9/11 Public Portal Document
INTERNAL REVIEW DRAFT
Alpha-Quartz
Before Cleaning Samples - There were three pre-cleaning wipe samples collected. Two of
the three samples were above the detection limit and the third sample was below the
detection limit.
Post P' Cleaning Samples - There were two air samples and four wipe samples collected
after the first cleaning. One of the two air samples detected alpha-quartz at a concentration
above the detection limit, at 0.008 mg/m^. The detection also was above the primary numeric
criterion of 0.001 mg/mf The other air sample was below the detection limit. Two of the
four wipe samples were below the detection limit, and the remaining two samples were
slightly above the detection limit. With the exception of the air sample that exceeded the
numeric criterion, the results indicate that the cleaning method used was able to reduce the
pre-cleaning concentration of alpha-quartz in settled dust, as the samples collected after the
first cleaning were lower than the pre-cleaning samples. However, since one air sample
exceeded the numeric criterion, additional air samples for alpha-quartz were collected.
Post 2^ Cleaning Samples - There were two air samples collected after the second cleaning.
The results indicate that both samples were below the detection limit. This indicates that the
second cleaning was able to reduce the alpha-quartz concentration in air to below the
detection limit.
Calcite
Before Cleaning Samples - There were three pre-cleaning wipe samples collected. All three
samples were below the detection limit.
Post P' Cleaning Samples - There were two air samples and four wipe samples collected
after the first cleaning. All of the samples were below the detection limit.
Post 2"‘‘ Cleaning Samples - There were two air samples collected after the second cleaning.
The results indicate that both samples were below the detection limit.
Cristobalite
Before Cleaning Samples - There were three pre-cleaning wipe samples collected. All three
samples were below the detection limit.
Post J" Cleaning Samples - There were two air samples and four wipe samples collected
after the first cleaning. All of the samples was below the detection limit.
Post 2^ Cleaning Samples - There were two air samples collected after the second cleaning.
The results indicate that both samples were below the detection limit.
58
CITY_21MC100_004205014
NYC-WTC_000276710
OCR can misread numbers and units. Confirm readings against the page image before using them.