Before Cleaning Samples - There were three pre-cleaning wipe samples collected. All three
samples were below the detection limit.
Post P' Cleaning Samples - There were two air samples and four wipe samples collected
after the first cleaning. All of the samples were below the detection limit.
Post 2^ Cleaning Samples - There were two air samples collected after the second cleaning.
The results indicate that both samples were below the detection limit.
MMVF
Before Cleaning Samples - There were three pre-cleaning wipe samples collected. All three
sample results indicate that MMVF was present above the detection limit.
Post J" Cleaning Samples - There were three air samples and five wipe samples collected
after the first cleaning. The results for the three air samples indicate that MMVF was present;
however, both samples were below the numeric criterion of 10 S/L. The results of the five
wipe samples indicate that four of the samples were below the detection limit and one sample
was at the detection limit. The MMVF concentrations after the first cleaning were lower than
the pre-cleaning samples. There is not a numeric criterion for MMVF in settled dust. Since
the air samples were below the numeric criterion and the MMVF in settled dust was greatly
reduced after the first cleaning, no additional samples were collected for MMVF.
PAHs
Before Cleaning Samples - There were three pre-cleaning wipe samples collected. All three
samples were below the detection limit and the TEF for each sample was below the numeric
criterion.
Post P' Cleaning Samples - There were four wipe samples collected after the first cleaning.
All of the samples were below the detection limit and the TEF for each sample was below the
numeric criterion of 300 pg/m\ Since all of the samples were below the detection limit and
the numeric criterion after the first cleaning, no additional samples were collected for PAHs.
Total Dust
Before Cleaning Samples - There were three pre-cleaning wipe samples collected; however,
EPA only requested to have one of the samples analyzed. The result indicates that there was
dust present.
Post P‘ Cleaning Samples - There were four wipe samples collected after the first cleaning;
however, EPA only requested to have two of the samples analyzed. Both samples indicate
that dust was present; however, the concentrations reported were an order of magnitude lower
than the pre-cleaning concentration. This indicates that the cleaning technique used was able