to remove dust. As total dust does not have a numeric criterion and the results indicate that
the concentration of dust was reduced, no additional samples were collected for total dust.
Unit 4B - This unit is located on the fourth floor. It is a 968 sq. ft. loft with four bedrooms facing
Cedar Street. No windows were blown-in and there was minimal dust accumulation in the dwelling
with the exception of the baseboard heating units, which contained visible dust. The unit has
hardwood floors and all of the tenant’s personal items were cleaned and sealed in bags prior to the
cleanup.
Cleaning method - This unit was cleaned using test method 2B. Test method 2B used a
Ridgid shop vacuum and Hoover upright vacuum with a HEPA filter for vacuuming the
floors and other surfaces. An air filtration device (AFD) was used during the cleaning
process. In addition, all horizontal surfaces were wet wiped. This cleaning method was used
for each cleaning event.
Numeric Criteria - This unit met the numeric criteria listed in Table 1 for each compound
after being cleaned once.
Asbestos
Before Cleaning Samples ~ Pre-cleaning wipe samples were collected for asbestos. The
results for these samples indicate that asbestos was present in the unit prior to cleaning. Two
of the five wipe samples were below the detection limit, although one of these samples had
chrysotile detected. The remaining three samples had chrysotile detected above the detection
limit.
Post P' Cleaning - There were post-cleaning air and wipe samples collected. The three air
samples were analyzed using PCM and TEM PCMe. The PCM results were all below the
secondary numeric criterion of 0.01 f/cc. The TEM PCMe results for each sample were
below the primary numeric criterion of 0.0009 f/cc and were reported as below the detection
limit.
The results for the five wipe samples that were collected indicate that asbestos was present in
two of the five samples, although one of these samples was below the detection limit. The
remaining three samples were below the detection limit.
Dioxin
Before Cleaning Samples - There were four pre-cleaning wipe samples collected and
analyzed for dioxin. The results indicate that there was dioxin present; however, the TEQ
concentrations for each sample were below the primary numeric criterion of 4 ng/m^.