Post P' Cleaning Samples - There were four post-cleaning wipe samples collected and
analyzed for dioxin. The results indicate that the TEQ concentrations for each sample were
below the primary numeric criterion of 4 ng/m^.
Gypsum
Before Cleaning Samples - There were four pre-cleaning wipe samples collected. The results
indicate that gypsum was not detected.
Post P' Cleaning Samples - There were two air samples and four wipe samples collected
after the first cleaning. The results indicate that gypsum was not detected in any sample.
Lead
Before Cleaning Samples - There were four pre-cleaning wipe samples collected. The results
indicate that lead was detected in three of the four wipe samples with two samples exceeding
the primary numeric criterion of 25 pg/ft^ One sample was slightly over the numeric
criterion with a result of 30 pg/ft^ while the second was twice the numeric criterion with a
result of 50 pg/ft^.
Post Cleaning Samples - There were two air samples and four wipe samples collected
after the first cleaning. The two air samples were above the detection limit but below the
primary numeric criterion of 1 pg/mf Three of the four wipe samples were below the
detection limit. The fourth wipe sample was above the detection limit but below the primary
numeric criterion. Since the numeric criterion was met for lead after the first cleaning, no
additional cleaning was necessary.
Alpha-Quartz
Before Cleaning Samples - There were four pre-cleaning wipe samples collected. One of the
four samples was above the detection limit and the other three samples were below the
detection limit.
Post J" Cleaning Samples - There were two air samples and four wipe samples collected
after the first cleaning. All of the samples were below the detection limit.
Calcite
Before Cleaning Samples - There were four pre-cleaning wipe samples collected. All four
samples were below the detection limit.
Post P' Cleaning Samples - There were two air samples and four wipe samples collected
after the first cleaning. All of the samples were below the detection limit.