Alpha-Quartz Before Cleaning Samples - Pre-cleaning air samples were not collected.

Post P' Cleaning Samples - Two air samples were collected after the first cleaning. The two air samples were below the detection limit. Because the samples were below the detection limits after the first cleaning, no additional samples were collected for analysis of alpha-quartz.

Calcite Before Cleaning Samples - Pre-cleaning air samples were not collected.

Post P' Cleaning Samples - Two air samples were collected after the first cleaning. All of the samples were below the detection limit. Because all of the samples were below the detection limit after the first cleaning, no additional samples were collected for analysis of calcite.

Cristobalite Before Cleaning Samples - Pre-cleaning air samples were not collected.

Post l^ Cleaning Samples - Two air samples were collected after the first cleaning. All of the samples were below the detection limit. Because all of the samples were below the detection limit after the first cleaning, no additional samples were collected for analysis of cristobalite.

Tridymite Before Cleaning Samples - Pre-cleaning air samples were not collected.

Post Cleaning Samples - Two air samples were collected after the first cleaning. All of the samples were below the detection limit. Because all of the samples were below the detection limit after the first cleaning, no additional samples were collected for analysis of tridymite.

MMVF Before Cleaning Samples - Two pre-cleaning air samples and three pre-cleaning wipe samples were collected. One of the two air samples was above the primary clearance criterion of 10 S/L and the other air sample was above the detection limit. The results for all three of the wipe samples indicate that MMVF was above the detection limit. This indicates that MMVF was present in the unit prior to cleaning.

Post P‘ Cleaning Samples - Three air samples and five wipe samples were collected after the first cleaning. The results for the three air samples indicate that MMVF was present, however, all three were below the primary clearance criterion of 10 S/L. The results of the five wipe samples indicate that three of the five samples were below the detection limit and the remaining two samples were at the detection limit. Although MMVF was still present after the first cleaning, the concentrations detected were much lower than the pre­ cleaning samples. There is not a clearance criterion for MMVF in settled dust. Because the air samples were below the primary clearance criterion and the MMVF in settled dust

50

CITY_21MC100_011105280

NYC-WTC_000195246

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000195246Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

No available related records indexed in this group.

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →