hardwood floors with no carpet and the majority of the personal items were disposed of prior to clean
up.
Cleaning Method - This unit was cleaned using test method 1A which used a Craftsman shop
vacuum and a Eureka upright with no HEPA filter. In addition, an air filtration device (AFD)
was not used. This method was used for the first two cleaning events. For the third cleaning
event the test method was changed to method 3B which used an industrial HEPA filtered
vacuum and AFD. Each method had all horizontal and vertical surfaces wet wiped.
Numeric Criteria - This unit met the numeric criteria listed in Table 1 for each compound
after being cleaned three times.
Asbestos
Before cleaning samples - Pre-cleaning micro vacuum and wipe samples were collected for
asbestos. These samples indicate that asbestos was present in the unit prior to cleaning. All
four of the micro vacuum samples detected chrysotile. Three of the four wipe samples
detected chrysotile, one of which also detected amosite. The fourth wipe sample was below
the detection limit.
Post P' Cleaning Samples - Post-cleaning air, micro vacuum, and wipe samples were
collected for asbestos. The PCM and TEM PCMe analyses could not be conducted due to
overloading of particulate matter on the filters.
The results of the four micro vacuum samples indicate that asbestos was present at levels
higher than those observed before cleaning.
Two of the five wipe samples were below the detection limit, although one of these samples
did detect chrysotile. The remaining three samples were above the detection limit and similar
or below the pre-cleaning samples.
Post 2'“‘ Cleaning - Post-cleaning samples included five asbestos air samples. The samples
could not be analyzed due to overloading of particulate matter on the filters. Due to this
situation, a third cleaning was conducted using a more aggi-essive cleaning method that used
an industrial HEPA vacuum and an AFD.
Post 3'^ Cleaning - There were six asbestos air samples collected after the third cleaning.
The samples were analyzed for PCM, TEM AHERA, and TEM PCMe. The results of the
PCM analysis indicate that three of the six samples were below the detection limit. The
remaining three samples were above the detection limit but below the secondary numeric
criterion of 0.01 f/cc. The TEM AHERA results indicate that all six samples were below the
detection limit. The TEM PCMe results also indicate that all six samples were below the
detection limit. This suggests that the cleaning techniques used for the third cleaning were
47
CITY_21MC100_004205003
NYC-WTC_000276699