NYC-WTC_000431857
EPA NYC Region 2 WTC response document, City data file.
44 shared non-person entities · 1 shared topics · similarity 0.996
machine-extracted · confidence unavailable · Check page ↗Interim final report noting organizations involved and plan for third-party review.
NYC-WTC_000363060–000363182OCR status: ok · source: pdftotext
NYC 9/11 Public Portal Document
Cleaning Method - This unit was cleaned using Test 2 A: a Ridgid® shop vacuum and a Eureka® upright vacuum with a HEPA filter. No AFDs were used. All horizontal surfaces were wet- wiped. This cleaning method was used for each cleaning event.
Cleaning Results - This unit met the clearance listed in Table 1.0 for each compound after being cleaned twice.
Asbestos Before Cleaning Samples - Six micro vacuum and five wipe samples were collected for asbestos. These samples indicate that asbestos was present in the unit prior to cleaning All six of the micro vacuum samples detected chrysotile above the detection limit. Two of the five wipe samples were below the detection limit, although one detected chrysotile. The remaining three samples were above the detection limit.
Post P' Cleaning Samples - Three air, six micro vacuum samples and five wipe samples were collected for asbestos. The samples were analyzed using PCM, TEM AHERA, and PCMe. The results for the PCM analysis indicate that two of the three samples were below the secondary numeric criterion of 0.01 f/cc. The third slightly exceeded this value with a concentration of 0 02 f/cc The TEM AHERA results indicate that all three samples were below the secondary numeric criterion of 0.022 S/cc. The PCMe results indicate that two of the three air samples were below the primary clearance criterion of 0.0009 S/cc. The third sample detected chrysotile and was at the primary clearance criterion of 0.0009 S/cc.
The results of the six micro vacuum samples indicate that asbestos was present at levels lower than those observed before cleaning.
The results of the five wipe samples indicate that asbestos was present in all of the samples at concentrations similar to or lower than those observed before cleaning.
Dipjdn Before Cleaning Samples - Four pre-cleaning wipe samples were collected and analyzed for dioxin. The results indicate that dioxin was present; however, the TEQ concentration for each sample was below the primary clearance criterion of 4 ng/m^.
Post Cleaning Samples - Four post-cleaning wipe samples were collected and analyzed for dioxin. The results indicate that there was dioxin present at concentrations lower than those observed in the pre-cleaning samples. In addition, the TEQ concentration for each sample was below the primary clearance criterion of 4 ng/m^. This indicates that the cleaning techniques were effective at reducing dioxin concentrations.
Gypsum Before Cleaning Samples - Pre-cleaning air samples were not collected.
Post Cleaning Samples - Two air samples were collected after the first cleaning. Gypsum was not detected above the detection limit of 0.016 mg/m^ for these samples.
67
CITY_21MC100_011063437
NYC-WTC_000363129
OCR can misread numbers and units. Confirm readings against the page image before using them.
Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.
NYC-WTC_000431857
EPA NYC Region 2 WTC response document, City data file.
44 shared non-person entities · 1 shared topics · similarity 0.996
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000195194
Document excerpt acknowledging contributors and outlining the collaborative scope of an EPA environmental protection study regarding the World Trade Center site.
45 shared non-person entities · 1 shared topics · similarity 0.995
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000276652
Table of contents for contaminants of [name] report and building sections.
32 shared non-person entities · 1 shared topics · similarity 0.994
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000145695
Form documenting the tracking and handling of environmental samples collected by the Department of Environmental Protection.
44 shared non-person entities · 1 shared topics · similarity 0.992
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000155174
Chain of custody documentation for cleanup and monitoring samples at 114 Liberty distributed among project team members.
12 shared non-person entities · 1 shared topics · similarity 0.965
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000138897
Internal DEP coordination regarding comments on 114 Liberty procedures and preparation of a response.
12 shared non-person entities · 1 shared topics · similarity 0.964
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000155286
Formal letter criticizing the EPA and DEP for alleged failures in cleaning asbestos and silica from 114 Liberty Street.
13 shared non-person entities · similarity 0.964
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000162938
Correspondence regarding monitoring activities and documentation for the asbestos cleanup at 114 Liberty Street in early 2003.
12 shared non-person entities · 1 shared topics · similarity 0.964
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000243565
EIA report for Law Department project at 100 Church Street by TRC.
18 shared non-person entities · similarity 0.964
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000102521
EPA letter confirming that primary and secondary clearance levels for asbestos and other contaminants were met at 114 Liberty Street.
9 shared non-person entities · similarity 0.964
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000243703
Environmental assessment prepared for NYC Law Department by TRC Engineers, April 8, 2002.
18 shared non-person entities · similarity 0.964
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000243668
Environmental assessment prepared for NYC Law Department by TRC Engineers, April 8, 2002.
18 shared non-person entities · similarity 0.964
machine-extracted · confidence unavailable · Check page ↗Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.
NYC-WTC_000145695
Form documenting the tracking and handling of environmental samples collected by the Department of Environmental Protection.
Similarity score 0.999 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000195194
Document excerpt acknowledging contributors and outlining the collaborative scope of an EPA environmental protection study regarding the World Trade Center site.
Similarity score 0.998 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000145695
Form documenting the tracking and handling of environmental samples collected by the Department of Environmental Protection.
Similarity score 0.990 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000145695
Form documenting the tracking and handling of environmental samples collected by the Department of Environmental Protection.
Similarity score 0.989 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000195194
Document excerpt acknowledging contributors and outlining the collaborative scope of an EPA environmental protection study regarding the World Trade Center site.
Similarity score 0.989 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000195194
Document excerpt acknowledging contributors and outlining the collaborative scope of an EPA environmental protection study regarding the World Trade Center site.
Similarity score 0.988 (not a probability)
machine-extracted · confidence unavailable · Check page ↗Machine-extracted building matches; verify each source. Buildings, never households.
Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.
NYC-WTC_000431857
EPA NYC Region 2 WTC response document, City data file.
Similar indexed content
NYC-WTC_000195194
Document excerpt acknowledging contributors and outlining the collaborative scope of an EPA environmental protection study regarding the World Trade Center site.
Similar indexed content
NYC-WTC_000276652
Table of contents for contaminants of [name] report and building sections.
Similar indexed content
NYC-WTC_000145695
Form documenting the tracking and handling of environmental samples collected by the Department of Environmental Protection.
Similar indexed content
NYC-WTC_000155174
Chain of custody documentation for cleanup and monitoring samples at 114 Liberty distributed among project team members.
Similar indexed content