NYC 9/11 Public Portal Document
INTERNAL REVIEW DRAFT
effective at reducing the particulate matter to levels that pennitted valid air samples to be
collected and analyzed, with the results indicating that all six samples were below the
primary numeric criterion of 0.0009 S/cc.
Dioxin
Before Cleaning Samples - There were three pre-cleaning wipe samples collected and
analyzed for dioxin. The results indicate that there was dioxin present and that the TEQ
concentration for one the three samples was above the numeric criterion of 4 ng/m \
Post J" Cleaning Samples - There were four post-cleaning samples collected and analyzed for
dioxin. The results indicate that there was dioxin present; however, the TEQ concentrations
were below the numeric criterion of 4ng/m^. This indicates that the cleaning teclmiques used
were effective at reducing the pre-cleaning concentrations of dioxin.
Gypsum
Before Cleaning Samples - There were three pre-cleaning wipe samples collected. The
results indicate gypsum was not detected above the detection limit range of 5 to 40 mg/m^
Post P' Cleaning Samples - There were two air samples and four wipe samples collected after
the first cleaning. The results indicate that gypsum was not detected above the detection limit
for the air samples and not detected above the detection limit for wipe samples.
Lead
Before Cleaning Samples - There were four micro vacuum samples and three wipe samples
collected. The results indicate lead was detected in all four micro vacuum samples at
concentrations above the comparison value. Two of the three wipe samples were detected at
concentrations above the primary numeric criteria of 25 pg/fF. The micro vacuum samples
exceeded the comparison value in a range of 39.4 pght’ to 135 pg/fF, and the two wipe
sample exceeded the primary numeric criteria at 48.7 pg/fri and 750 pg/ff. This indicates
that lead was present prior to cleaning.
Post P' Cleaning Samples - There were two air samples, four micro vacuum samples, and
four wipe samples collected after the first cleaning. The two air samples were below the
numeric criterion. The results of the micro vacuum and wipe samples show that all but one
micro vacuum sample (26.9 met the comparison value or primary numeric criterion
for lead.
Post 2"‘‘ Cleaning Samples - There were two air samples collected after the second cleaning.
Both samples were detected at concentrations below the numeric criterion.
Alpha Quartz
48
CITY_21MC100_004205004
NYC-WTC_000276700
OCR can misread numbers and units. Confirm readings against the page image before using them.