Before Cleaning Samples - There were three pre-cleaning wipe samples collected. All three
samples had alpha-quartz detected.
Post Cleaning Samples - There were two air and four wipe samples collected after the first
cleaning. All samples were below the detection limit. This indicates that the cleaning
techniques were effective at reducing the pre-cleaning concentrations of silica.
Calcite
Before Cleaning Samples - There were four pre-cleaning wipe samples collected. Three of
the four samples were below the detection limit. The fourth was above the detection limit.
Post P' Cleaning Samples - There were two air samples and four wipe samples collected
after the first cleaning. All of the samples were below the detection limit. Since all of the
samples were below the detection limits after the first cleaning, no additional samples were
collected for calcite.
Cristobalite
Before Cleaning Samples - There were four pre-cleaning wipe samples collected. All four
samples were below the detection limit.
Post P' Cleaning Samples - There were two air samples and four wipe samples collected
after the first cleaning. All of the samples were below the detection limit. Since all of the
samples were below the detection limits after the first cleaning, no additional samples were
collected for cristobalite.
Tridymite
Before Cleaning Samples - There were four pre-cleaning wipe samples collected. All four
samples were below the detection limit.
Post P' Cleaning Samples - There were two air samples and four wipe samples collected
after the first cleaning. All of the samples were below the detection limit. Since all of the
samples were below the detection limits after the first cleaning, no additional samples were
collected for tridymite.
MMVF
Before Cleaning Samples - There were three pre-cleaning wipe samples collected. The three
wipe samples had MMVF detected in concentrations from 343.39 S/L to 744.01 S/L. This
indicates that MMVF was present prior to cleaning.
Post P' Cleaning Samples - There were three air samples and five wipe samples collected
after the first cleaning. All of the air sample results indicate that MMVF was present but at
49