NYC 9/11 Public Portal Document
INTERNAL REVIEW DRAFT
levels below the numeric criterion of 10 S/L. All of the wipe sample results were above the
detection limit and at concentrations similar or below the pre-cleaning samples.
Post 2"^ Cleaning - There were five air samples collected after the second cleaning. Four of
the five samples were below the numeric criterion of 10 S/L. However, one sample exceeded
the numeric criterion at 91.796 S/L; this value was further evaluated and determined to be
invalid due to an equipment malfunction which resulted in the collection of a volume of air
significantly less than the other four samples. It should be noted that the four other post-2nd
cleaning air samples, and the three post-1st cleaning air samples were below the applicable
health-based benchmark.
PAHs
Before Cleaning Samples - There were three pre-cleaning wipe samples collected. Two of
the three samples were below the detection limit and the calculated TEF for these two
samples were below the primary numeric criterion. The third sample had twelve PAH
compounds detected and the calculated TEF for this sample exceeded the TEF of 300 pg/m^
with a value of 1046.6 pg/m^.
Post P' Cleaning Samples, Test IA - There were four post-cleaning wipe samples collected.
All four samples were below the detection limit, and the TEF for each sample was below the
numeric criterion of 300 pg/mT This indicates that the cleaning techniques used were
effective in reducing the elevated dioxin pre-cleaning concentrations.
Total Dust
Before Cleaning Samples - There were three pre-cleaning wipe samples collected; however,
EPA only requested to have one of the samples analyzed. The results indicate that dust was
present below the detection limit.
Post P' Cleaning Samples, Test ]A - There were four post-cleaning wipe samples collected;
however, EPA only requested to have two of the samples analyzed. The analyzed samples
indicate that dust was present at concentrations higher than the pre-cleaning concentrations.
However, since total dust does not have a numeric criterion, no additional sampling for total
dust was performed.
Unit 3D - This is a 968 sq. ft. loft with three bedrooms facing the World Trade Center site. This unit
had windows blown in and there was significant accumulation of dust in the dwelling. The unit has
hardwood floors with no carpet and the majority of the personal items, except for three pieces of
hardwood furniture, were disposed of prior to clean up.
Cleaning Method - This unit was cleaned using test method 1 A. Test method 1A used a
Ridgid shop vacuum and a Hoover upright without a HEP A filter. There were no air
50
CITY_21MC100_004205006
NYC-WTC_000276702
OCR can misread numbers and units. Confirm readings against the page image before using them.