Post 2"“^ Cleaning Samples - Two air samples were collected after the second cleaning Both samples detected concentrations below the primary clearance criterion.

Alpha-Quartz Before Cleaning Samples - Pre-cleaning air samples were not collected

Post P‘ Cleaning Samples - Two air samples were collected after the first cleaning. All samples were below the detection limit.

Calcite Before Cleaning Samples - Pre-cleaning air samples were not collected.

Post P‘ Cleaning Samples - Two air samples were collected after the first cleaning. All of the samples were below the detection limit Because all of the samples were below the detection limit after the first cleaning, no additional samples were collected for analysis of calcite.

Cristobalite Before Cleaning Samples - Pre-cleaning air samples were not collected.

Post P‘ Cleaning Samples - Two air samples were collected after the first cleaning. All of the samples were below the detection limit Since all of the samples were below the detection limit after the first cleaning, no additional samples were collected for analysis of cristobalite

Tridymite Before Cleaning Samples - Pre-cleaning air samples were not collected.

Post P' Cleaning Samples - Two air samples were collected after the first cleaning. All of the samples were below the detection limit. Since all of the samples were below the detection limit after the first cleaning, no additional samples were collected for analysis of tridymite.

MMVF Before Cleaning Samples - Three pre-cleaning wipe samples were collected. The three wipe samples detected MMVF in concentrations from 343.39 S/L to 744.01 S/L. This indicates that MMVF was present prior to cleaning.

Post P‘ Cleaning Samples - Three air samples and five wipe samples were collected after the first cleaning. All of the air sample results indicate that MMAT was present at levels below the primary clearance criterion of 10 S/L. All of the wipe sample results were above the detection limit and at concentrations similar or lower than the pre-cleaning samples.

Post 2”‘^ Cleaning - Five air samples were collected after the second cleaning. Four of the five samples were below the primary clearance criterion of 10 S/L. However, one sample exceeded the primary clearance criterion at 91.796 S/L. This value was further evaluated

53

CITY_21MC100_011063423

NYC-WTC_000363115

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000363115Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →