samples were below the detection limits after the first cleaning, no additional samples were
collected for tridymite.
MMVF
Before Cleaning Samples - There were two pre-cleaning air samples and three pre-cleaning
wipe samples collected. One of the two air samples was above the primary numeric criterion
of 10 S/L and the other air sample was above the detection limit. The results for all three of
the wipe samples indicate that MMVF was above the detection limit. This indicates that
MMVF was present in the unit prior to cleaning.
Post P' Cleaning Samples - There were three air samples and five wipe samples collected
after the first cleaning. The results for the three air samples indicate that MMVF was present;
however, all three samples were below the numeric criterion of 10 S/L. The results of the
five wipe samples indicate that three of the five samples were below the detection limit and
the remaining two samples were at the detection limit. Although MMVF was still present
after the first cleaning, the concentrations detected were much lower than the pre-cleaning
samples. There is not a numeric criterion for MMVF in settled dust. Since the air samples
were below the numeric criterion and the MMVF in settled dust was reduced after the first
cleaning, no additional samples were collected for MMVF.
PAHs
Before Cleaning Samples - There were four pre-cleaning wipe samples collected. All four
samples were below the detection limit and the TEF for each sample was below the numeric
criterion.
Post P' Cleaning Samples - There were four wipe samples collected after the first cleaning.
All of the samples were below the detection limit and the TEE for each sample was below the
numeric criterion of 300 p-g/m^. Since all of the samples were below the detection limit and
the numeric criterion after the first cleaning, no additional samples were collected for PAHs.
Total Dust
Before Cleaning Samples - There were four pre-cleaning wipe samples collected; however,
EPA only requested to have two of the samples analyzed. The results indicate that the total
dust was below the detection limit.
Post P' Cleaning Samples - There were four wipe samples collected after the first cleaning;
however, EPA only requested to have one of the samples analyzed. The result indicates that
dust was present. As total dust does not have a numeric criterion, no additional samples were
collected for total dust.
Unit 3C - This is 655 sq. ft. loft with 2 bedrooms facing the World Trade Center site. This unit had
windows blown in and there was significant accumulation of dust in the dwelling. The unit has