Post 2^ Cleaning Samples - Two lead wipe samples were collected after the second cleaning
in the area where the post-first cleaning lead exceedance occurred. One of the samples was
received broken at the laboratory and was not analyzed. The other sample was below the
detection limit and below the numeric criterion. The results from the second cleaning
indicate that the cleaning technique was effective in removing the elevated concentration of
lead that was observed after the first cleaning.
Alpha-Quartz
Before Cleaning Samples - There were four pre-cleaning wipe samples collected. Two of the
four samples were below the detection limit and the other two samples had alpha-quartz
detected.
Post j" Cleaning Samples - There were two air samples and four wipe samples collected
after the first cleaning. The two air samples and three of the four wipe samples were below
the detection limit. The fourth wipe sample was slightly above the detection limit. Since all
of the samples were below or near the detection limits after the first cleaning, no additional
samples were collected for alpha-quartz.
Calcite
Before Cleaning Samples - There were four pre-cleaning wipe samples collected. All four
samples were below the detection limit.
Post P' Cleaning Samples - There were two air samples and four wipe samples collected
after the first cleaning. All of the samples were below the detection limit. Since all of the
samples were below the detection limits after the first cleaning, no additional samples were
collected for calcite.
Cristobalite
Before Cleaning Samples - There were four pre-cleaning wipe samples collected. All four
samples were below the detection limit.
Post J" Cleaning Samples - There were two air samples and four wipe samples collected
after the first cleaning. All of the samples were below the detection limit. Since all of the
samples were below the detection limits after the first cleaning, no additional samples were
collected for cristobalite.
Tridymite
Before Cleaning Samples - There were four pre-cleaning wipe samples collected. All four
samples were below the detection limit.
Post P' Cleaning Samples - There were two air samples and four wipe samples collected
after the first cleaning. All of the samples were below the detection limit. Since all of the