NYC Law Department release
Independent mirror · updated as the City releases more · v1.5.1
☕ Buy me a coffee
← Document results/Unboxed/No folder label
Document / 428 pages

EPA WTC interim report comments, 2003

Machine-extracted title · confidence 28%

Comments on EPA interim report regarding World Trade Center collapse from 2003.

NYC-WTC_000251148–000251575
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

L: EPA refusal to use electron microscopesfor dust testing - 224

Why TEM electron microscope asbestos methods are needed for WTC dust

Because of the force of the WTC implosion, asbestos fibers were highly pulverized into smaller than usual fiber sizes. With the old PLM light microscope method, many of the thin WTC asbestos fibers, fibers that are still longer than 5 micrometers long (5 pg„ or 5 microns), cannot be seen." EPA has recognized the limitations of the old PLM light microscope method for years. EPA developed, and required the use of the newer electron microscopy method for bulk asbestos materials through oflBcial published guidance.

The following is a description of the need for PLM versus TEM testing of asbestos;

The importance of using instruments with the appropriate resolution when counting asbestos fibers is further emphasized in that a single "fibril" of chrysotile may be as thin as 50nm while those of amphiboles are larger at approximately 500nm [Mueller and Stanley, 1975]. Thus counting fibers with the light microscope from either environmental samples or from tissue, yields data which, at best, provide information on only a small percentage of the overall fiber burden since the diameters of most asbestos fibers are tielow the limit of resolution of the light microscope [Ashcroft and Heppleston, 1973; Crossman et al., 1996; Pooley and Ranson, 1986; Murphy et al., 1986]. It was the recognition of this limitation of the light microscope for asbestos fiber analysis that resulted in the analytical transmission electron microscope being defined as the "state of the art" instrument for analysis of air samples for asbestos under the Asbestos Hazard Emergency Response Act (Title II of the Toxic Substance Control Act 15, U.S.C. Sections 2641 through 2654). The counting protocol when using TEM provides not only a morphological definition of the structures to be counted, but allows the analyst the capability to use magnification appropriate to "see" those structures that are below the level of detection by the light microscope. Simply because the analytical transmission electron microscope is used in a count does not mean the data reflect a true representation of the fiber burden because the scan must be made at a sufficiently high magnification to permit detection of short as well as long thin fibers [Murai et al., 1994].

This issue is of particular relevance when discussing the subject of fiber length and pathogenicity since results from models in which fiber length was determined solely by the light microscope must be critiqued with these limitations in mind.

[Accepted for publication in the American Journal of Industrial Medicine, 4/28/03, Asbestos Fiber Length as Related to Potential Pathogenicity: A Critical Review, Ronald F. Dodson, Ph.D., FCCP, FAHA; MarkA.L. Atkinson, M.A., D.Phil.; and Jeffrey L. Levin, M.D., M.S.P.H., The University of Texas Health Center at Tyler, Tyler, TX]

EPA reverses - performs TEM tests for 110 Liberty St. study near Ground Zero

Long after EPA and the NYC DEP instructed NYC citizens and health officials that dusts in the interior of buildings was not hazardous unless it contained more than 1% asbestos, as measured

NYC-WTC_000251380

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000251380Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

No available related records indexed in this group.

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →